Literature DB >> 22226405

Influence of stent configuration on cerebral aneurysm fluid dynamics.

M Haithem Babiker1, L Fernando Gonzalez, Justin Ryan, Felipe Albuquerque, Daniel Collins, Arius Elvikis, David H Frakes.   

Abstract

Embolic coiling is the most popular endovascular treatment available for cerebral aneurysms. Nevertheless, the embolic coiling of wide-neck aneurysms is challenging and, in many cases, ineffective. Use of highly porous stents to support coiling of wide-neck aneurysms has become a common procedure in recent years. Several studies have also demonstrated that high porosity stents alone can significantly alter aneurysmal hemodynamics, but differences among different stent configurations have not been fully characterized. As a result, it is usually unclear which stent configuration is optimal for treatment. In this paper, we present a flow study that elucidates the influence of stent configuration on cerebral aneurysm fluid dynamics in an idealized wide-neck basilar tip aneurysm model. Aneurysmal fluid dynamics for three different stent configurations (half-Y, Y and, cross-bar) were first quantified using particle image velocimetry and then compared. Computational fluid dynamics (CFD) simulations were also conducted for selected stent configurations to facilitate validation and provide more detailed characterizations of the fluid dynamics promoted by different stent configurations. In vitro results showed that the Y stent configuration reduced cross-neck flow most significantly, while the cross-bar configuration reduced velocity magnitudes within the aneurysmal sac most significantly. The half-Y configuration led to increased velocity magnitudes within the aneurysmal sac at high parent-vessel flow rates. Experimental results were in strong agreement with CFD simulations. Simulated results indicated that differences in fluid dynamic performance among the different stent configurations can be attributed primarily to protruding struts within the bifurcation region.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22226405     DOI: 10.1016/j.jbiomech.2011.12.016

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  13 in total

1.  Y-crossing of braided stents with stents and flow diverters does not cause significant stenosis in bench-top studies.

Authors:  Alina Makoyeva; Tim E Darsaut; Igor Salazkin; Jean Raymond
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

2.  The effect of Dean, Reynolds and Womersley numbers on the flow in a spherical cavity on a curved round pipe. Part 2. The haemodynamics of intracranial aneurysms treated with flow-diverting stents.

Authors:  Michael C Barbour; Fanette Chassagne; Venkat K Chivukula; Nathanael Machicoane; Louis J Kim; Michael R Levitt; Alberto Aliseda
Journal:  J Fluid Mech       Date:  2021-03-31       Impact factor: 3.627

3.  Flow diversion for complex middle cerebral artery aneurysms.

Authors:  Mario Zanaty; Nohra Chalouhi; Stavropoula I Tjoumakaris; L Fernando Gonzalez; Robert Rosenwasser; Pascal Jabbour
Journal:  Neuroradiology       Date:  2014-02-18       Impact factor: 2.804

4.  Hemodynamics of 8 different configurations of stenting for bifurcation aneurysms.

Authors:  K Kono; T Terada
Journal:  AJNR Am J Neuroradiol       Date:  2013-04-11       Impact factor: 3.825

5.  Higher oscillatory shear index is related to aneurysm recanalization after coil embolization in posterior communicating artery aneurysms.

Authors:  Tackeun Kim; Chang Wan Oh; Jae Seung Bang; Seung Pil Ban; Si Un Lee; Young Deok Kim; O-Ki Kwon
Journal:  Acta Neurochir (Wien)       Date:  2020-10-10       Impact factor: 2.816

6.  Computational Fluid Dynamics Study of Bifurcation Aneurysms Treated with Pipeline Embolization Device: Side Branch Diameter Study.

Authors:  Abraham Yik-Sau Tang; Wai-Choi Chung; Eric Tian-Yang Liu; Jie-Qiong Qu; Anderson Chun-On Tsang; Gilberto Ka-Kit Leung; Kar-Ming Leung; Alfred Cheuk-Hang Yu; Kwok-Wing Chow
Journal:  J Med Biol Eng       Date:  2015-06-30       Impact factor: 1.553

7.  Particle imaging velocimetry evaluation of intracranial stents in sidewall aneurysm: hemodynamic transition related to the stent design.

Authors:  Pierre Bouillot; Olivier Brina; Rafik Ouared; Karl-Olof Lovblad; Mohamed Farhat; Vitor Mendes Pereira
Journal:  PLoS One       Date:  2014-12-03       Impact factor: 3.240

8.  Y-configuration Stent-assisted Coil Embolization for Wide-necked Intracranial Bifurcation Aneurysms.

Authors:  Kwangho Lee; Hyun Park; Insung Park; Sukh Que Park; O-Ki Kwon; Jongwoo Han
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2016-12-31

9.  LVIS Jr Device for Y-Stent-Assisted Coil Embolization of Wide-Neck Intracranial Aneurysms: A Multicenter Experience.

Authors:  Edgar A Samaniego; Aldo A Mendez; Thanh N Nguyen; Vladimir Kalousek; Waldo R Guerrero; Sudeepta Dandapat; Guilherme Dabus; Italo Linfante; Ameer E Hassan; Alexander Drofa; Evgueni Kouznetsov; David Leedahl; David Hasan; Alberto Maud; Santiago Ortega-Gutierrez
Journal:  Interv Neurol       Date:  2018-04-03

10.  Hemodynamic effects of stent struts versus straightening of vessels in stent-assisted coil embolization for sidewall cerebral aneurysms.

Authors:  Kenichi Kono; Aki Shintani; Tomoaki Terada
Journal:  PLoS One       Date:  2014-09-23       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.