Literature DB >> 22225315

An efficient inverse radiotherapy planning method for VMAT using quadratic programming optimization.

W Hoegele1, R Loeschel, N Merkle, P Zygmanski.   

Abstract

PURPOSE: The purpose of this study is to investigate the feasibility of an inverse planning optimization approach for the Volumetric Modulated Arc Therapy (VMAT) based on quadratic programming and the projection method. The performance of this method is evaluated against a reference commercial planning system (eclipse(TM) for rapidarc(TM)) for clinically relevant cases.
METHODS: The inverse problem is posed in terms of a linear combination of basis functions representing arclet dose contributions and their respective linear coefficients as degrees of freedom. MLC motion is decomposed into basic motion patterns in an intuitive manner leading to a system of equations with a relatively small number of equations and unknowns. These equations are solved using quadratic programming under certain limiting physical conditions for the solution, such as the avoidance of negative dose during optimization and Monitor Unit reduction. The modeling by the projection method assures a unique treatment plan with beneficial properties, such as the explicit relation between organ weightings and the final dose distribution. Clinical cases studied include prostate and spine treatments. The optimized plans are evaluated by comparing isodose lines, DVH profiles for target and normal organs, and Monitor Units to those obtained by the clinical treatment planning system eclipse(TM).
RESULTS: The resulting dose distributions for a prostate (with rectum and bladder as organs at risk), and for a spine case (with kidneys, liver, lung and heart as organs at risk) are presented. Overall, the results indicate that similar plan qualities for quadratic programming (QP) and rapidarc(TM) could be achieved at significantly more efficient computational and planning effort using QP. Additionally, results for the quasimodo phantom [Bohsung et al., "IMRT treatment planning: A comparative inter-system and inter-centre planning exercise of the estro quasimodo group," Radiother. Oncol. 76(3), 354-361 (2005)] are presented as an example for an extreme concave case.
CONCLUSION: Quadratic programming is an alternative approach for inverse planning which generates clinically satisfying plans in comparison to the clinical system and constitutes an efficient optimization process characterized by uniqueness and reproducibility of the solution.

Mesh:

Year:  2012        PMID: 22225315     DOI: 10.1118/1.3671922

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Optimization of dose distributions of target volumes and organs at risk during stereotactic body radiation therapy for pancreatic cancer with dose-limiting auto-shells.

Authors:  Yangsen Cao; Xiaofei Zhu; Xiaoping Ju; Yongming Liu; Chunshan Yu; Yongjian Sun; Zhitao Dai; Xueling Guo; Huojun Zhang
Journal:  Radiat Oncol       Date:  2018-01-22       Impact factor: 3.481

2.  Inverse treatment planning for spinal robotic radiosurgery: an international multi-institutional benchmark trial.

Authors:  Oliver Blanck; Lei Wang; Wolfgang Baus; Jimm Grimm; Thomas Lacornerie; Joakim Nilsson; Sergii Luchkovskyi; Isabel Palazon Cano; Zhenyu Shou; Myriam Ayadi; Harald Treuer; Romain Viard; Frank-Andre Siebert; Mark K H Chan; Guido Hildebrandt; Jürgen Dunst; Detlef Imhoff; Stefan Wurster; Robert Wolff; Pantaleo Romanelli; Eric Lartigau; Robert Semrau; Scott G Soltys; Achim Schweikard
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.