Literature DB >> 22223721

Survey of the interventional cardiology procedures in Italy.

Gaetano Compagnone1, Francesco Campanella, Sara Domenichelli, Sergio Lo Meo, Marco Bonelli, Stefania delle Canne, Paola Isoardi, Michele Marinaro, Massimo Ursetta, Roberta Curini.   

Abstract

Interventional cardiology procedures are increasing because they offer many advantages to patients compared with other techniques: therefore the Italian National Institution for Insurance against Accidents at Work decided to start a survey for monitoring the state-of-the-art regarding the professionals involved in those procedures. The survey covered six cardiology and medical physics Italian departments. Each centre was asked to record 10 examinations for five types of procedures: coronary angiography (CA), electrophysiology studies (ES), pacemaker implantation (PI), percutaneous transluminal coronary angioplasty (PTCA) and radiofrequency catheter ablation (RA). For each examination all the centres were requested to fill in a questionnaire containing information regarding the operator performing the examination, the patient and the procedure. A total of 290 examinations were recorded: 103 CA, 14 ES, 68 PI, 79 PTCA and 26 RA. As occupational doses are strongly related to patient doses, both patients and operators radiation dose data are reported. Ratios of maximum to minimum mean patient doses across the hospitals surveyed were 2.0, 3.9, 7.0, 1.8 and 1.4 for CA, ES, PI, PTCA and RA, respectively. The calculated rounded mean dose-area product values across all participating hospitals were comparable with other values reported in the literature. In general, specific radiation protection tools were used by all operators performing different procedures in all hospitals. A major issue in this survey was the absence of information about correlation between staff and patient doses in a single procedure: future studies could be more aimed to prospective goals where occupational exposures per procedure are monitored specifically.

Entities:  

Mesh:

Year:  2012        PMID: 22223721     DOI: 10.1093/rpd/ncr417

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  1 in total

1.  Summary of the Italian inter-society recommendations for radiation protection optimization in interventional radiology.

Authors:  Gaetano Compagnone; Renato Padovani; Maria Antonietta D'Avanzo; Sveva Grande; Francesco Campanella; Antonella Rosi
Journal:  Radiol Med       Date:  2018-01-06       Impact factor: 3.469

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.