Literature DB >> 22223588

Fluorescent and colorimetric probes for mercury(II): tunable structures of electron donor and π-conjugated bridge.

Xiaohong Cheng1, Shuang Li, Huizhen Jia, Aoshu Zhong, Cheng Zhong, Jun Feng, Jingui Qin, Zhen Li.   

Abstract

A new series of intramolecular-charge-transfer (ICT) molecules (compounds 1, 2, and 3) were synthesized by attaching various electron-donating thiophenes groups to a triphenylamine backbone with an aldehyde group as the electron acceptor. Based on the protection reaction between ethanethiol and aldehyde, the corresponding dithioacetals (compounds S1, S2, and S3) were prepared to serve as novel colorimetric and fluorescent chemosensors for Hg(2+) ions. Also, compound S1 was further utilized to construct the chemical-reaction-based conjugated polymer probe (PS1) towards Hg(2+) ions. In the presence of as little as 10 nM Hg(2+), compound PS1 displayed an apparent change in the fluorescent intensity. The sensing processes were revealed to be mediated by ICT, as confirmed by time-dependent DFT calculations. Furthermore, compound S1 was successfully applied to microscopic imaging for the detection of Hg(2+) in HeLa cells with ratiometric fluorescent methods.
Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22223588     DOI: 10.1002/chem.201102376

Source DB:  PubMed          Journal:  Chemistry        ISSN: 0947-6539            Impact factor:   5.236


  4 in total

1.  Anthracene-Based Highly Selective and Sensitive Fluorescent "Turn-on" Chemodosimeter for Hg2.

Authors:  Chinna Ayya Swamy P; Jeyabalan Shanmugapriya; Subramanian Singaravadivel; Gandhi Sivaraman; Duraisamy Chellappa
Journal:  ACS Omega       Date:  2018-10-01

Review 2.  A Comprehensive Review on Thiophene Based Chemosensors.

Authors:  Rikitha S Fernandes; Nitinkumar S Shetty; Priyanka Mahesha; Santhosh L Gaonkar
Journal:  J Fluoresc       Date:  2021-10-08       Impact factor: 2.217

3.  A relay strategy for the mercury (II) chemodosimeter with ultra-sensitivity as test strips.

Authors:  Zhijun Ruan; Conggang Li; Jian-Rong Li; Jingui Qin; Zhen Li
Journal:  Sci Rep       Date:  2015-11-06       Impact factor: 4.379

4.  An Ionic 1,4-Bis(styryl)benzene-Based Fluorescent Probe for Mercury(II) Detection in Water via Deprotection of the Thioacetal Group.

Authors:  Van Sang Le; Ji-Eun Jeong; Huy Tuan Huynh; Jiae Lee; Han Young Woo
Journal:  Sensors (Basel)       Date:  2016-12-07       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.