Shielding effect of a customized intraoral mold including lead material in high-dose-rate 192-Ir brachytherapy for oral cavity cancer.

Takaharu Kudoh1, Hitoshi Ikushima, Eiichi Honda.   

Abstract

A high-dose-rate (HDR) 192-Ir brachytherapy using a customized intraoral mold is effective for superficial oral cavity cancer, and the surrounding normal tissue is kept away from the radioactive source with gauze pads and/or mouth piece for reducing the dose on the normal tissues. In the Tokushima university hospital, the mold has a lead shield which utilizes the space prepared with sufficient border-molding by a specific dental technique using modeling compound. In HDR 192-Ir brachytherapy using a lead shielded customized intraoral mold, there are no reports measuring the absorbed dose. The purpose of the present study is to measure the absorbed dose and discuss the optimum thickness of lead in HDR 192-Ir brachytherapy using a customized intraoral mold with lead shield using a 1 cm thickness mimic mold. The thickness of lead in the mold could be changed by varying the arrangement of 0.1 cm thickness sheet of the acrylic resin plate and lead. The measured doses at the lateral surface of the mold with thermo-luminescence dosimeter were reduced to 1.12, 0.79, 0.57, 0.41, 0.31, 0.24 and 0.19 Gy and the ratios to the prescription dose were reduced to 56, 40, 29, 21, 16, 12 and 10 percent as lead thickness increased from 0 to 0.6 cm in 0.1 cm increments, respectively. A 0.3 cm thickness lead was considered to be required for a 1 cm thickness mold, and it was necessary to thicken the lead as much as possible with the constraint of limited space in the oral cavity, especially at the fornix vestibule.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22223463     DOI: 10.1269/jrr.11102

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  4 in total

1.  Intraoral angiosarcoma: treatment with a brachytherapy prosthesis.

Authors:  Evan B Rosen; Eugene Ko; Suzanne Wolden; Joseph M Huryn; Cherry L Estilo
Journal:  J Prosthet Dent       Date:  2014-11-20       Impact factor: 3.426

2.  Utility of intraoral stents in external beam radiotherapy for head and neck cancer.

Authors:  Hiroshi Doi; Masao Tanooka; Toshihisa Ishida; Kuniyasu Moridera; Kenji Ichimiya; Kazuo Tarutani; Kazuhiro Kitajima; Masayuki Fujiwara; Hiromitsu Kishimoto; Norihiko Kamikonya
Journal:  Rep Pract Oncol Radiother       Date:  2017-05-08

3.  Designing and Dosimetry of a Shield for Photon Fields of Radiation Therapy in Oral Cavity Cancer.

Authors:  Keyvan Jabbari; Somayeh Senobari; Mahnaz Roayaei; Masoumeh Rostampour
Journal:  J Med Signals Sens       Date:  2015 Apr-Jun

4.  Effect of a lead block on alveolar bone protection in image-guided high-dose-rate interstitial brachytherapy for tongue cancer: using model-based dose calculation algorithms to correct for inhomogeneity.

Authors:  Hironori Akiyama; Ken Yoshida; Tadashi Takenaka; Tadayuki Kotsuma; Koji Masui; Hajime Monzen; Iori Sumida; Yutaka Tsujimoto; Mamoru Miyao; Hiroki Okumura; Taiju Shimbo; Hideki Takegawa; Naoya Murakami; Koji Inaba; Tairo Kashihara; Zoltán Takácsi-Nagy; Nikolaos Tselis; Hideya Yamazaki; Eiichi Tanaka; Keiji Nihei; Yoshiko Ariji
Journal:  J Contemp Brachytherapy       Date:  2022-02-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.