Literature DB >> 22217735

A free database of radionuclide voxel S values for the dosimetry of nonuniform activity distributions.

N Lanconelli1, M Pacilio, S Lo Meo, F Botta, A Di Dia, A Torres Aroche, M A Coca Pérez, M Cremonesi.   

Abstract

The increasing availability of SPECT/CT devices with advanced technology offers the opportunity for the accurate assessment of the radiation dose to the biological target volume during radionuclide therapy. Voxel dosimetry can be performed employing direct Monte Carlo radiation transport simulations, based on both morphological and functional images of the patient. On the other hand, for voxel dosimetry calculations the voxel S value method can be considered an easier approach than patient-specific Monte Carlo simulations, ensuring a good dosimetric accuracy at least for anatomic regions which are characterized by uniform density tissue. However, this approach has been limited because of the lack of tabulated S values for different voxel dimensions and radionuclides. The aim of this work is to provide a free dataset of values which can be used for voxel dosimetry in targeted radionuclide studies. Seven different radionuclides (89Sr, 90Y, 131I, 153Sm, 177Lu, 186Re, 188Re), and 13 different voxel sizes (2.21, 2.33, 2.4, 3, 3.59, 3.9, 4, 4.42, 4.8, 5, 6, 6.8 and 9.28 mm) are considered. Voxel S values are calculated performing simulations of monochromatic photon and electron sources in two different homogeneous tissues (soft tissue and bone) with DOSXYZnrc code, and weighting the contributions on the basis of the radionuclide emission spectra. The outcomes are validated by comparison with Monte Carlo simulations obtained with other codes (PENELOPE and MCNP4c) performing direct simulation of the radionuclide emission spectra. The differences among the different Monte Carlo codes are of the order of a few per cent when considering the source voxel and the bremsstrahlung tail, whereas the highest differences are observed at a distance close to the maximum continuous slowing down approximation range of electrons. These discrepancies would negligibly affect dosimetric assessments. The dataset of voxel S values can be freely downloaded from the website www.medphys.it.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22217735     DOI: 10.1088/0031-9155/57/2/517

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  3D dosimetry in patients with early breast cancer undergoing Intraoperative Avidination for Radionuclide Therapy (IART) combined with external beam radiation therapy.

Authors:  Mahila E Ferrari; Marta Cremonesi; Amalia Di Dia; Francesca Botta; Concetta De Cicco; Anna Sarnelli; Piernicola Pedicini; Michele Calabrese; Roberto Orecchia; Guido Pedroli; Giovanni Paganelli
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-08-14       Impact factor: 9.236

2.  Patient-specific dosimetry for intracavitary 32P-chromic phosphate colloid therapy of cystic brain tumours.

Authors:  Ana M Denis-Bacelar; Marina Romanchikova; Sarah Chittenden; Frank H Saran; Henry Mandeville; Yong Du; Glenn D Flux
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-06-06       Impact factor: 9.236

3.  Pre- and post-treatment image-based dosimetry in90Y-microsphere radioembolization using the TOPAS Monte Carlo toolkit.

Authors:  Alejandro Bertolet; Eric Wehrenberg-Klee; Mislav Bobić; Clemens Grassberger; Joseph Perl; Harald Paganetti; Jan Schuemann
Journal:  Phys Med Biol       Date:  2021-12-29       Impact factor: 3.609

4.  Accuracy of two dosimetry software programs for 177Lu radiopharmaceutical therapy using voxel-based patient-specific phantoms.

Authors:  Keamogetswe Ramonaheng; Johannes A van Staden; Hanlie du Raan
Journal:  Heliyon       Date:  2022-07-06

5.  A review of 3D image-based dosimetry, technical considerations and emerging perspectives in 90Y microsphere therapy.

Authors:  Jim O' Doherty
Journal:  J Diagn Imaging Ther       Date:  2015-04-28

Review 6.  Preclinical Voxel-Based Dosimetry in Theranostics: a Review.

Authors:  Arun Gupta; Min Sun Lee; Joong Hyun Kim; Dong Soo Lee; Jae Sung Lee
Journal:  Nucl Med Mol Imaging       Date:  2020-04-19

7.  A Comparison of Techniques for (90)Y PET/CT Image-Based Dosimetry Following Radioembolization with Resin Microspheres.

Authors:  Alexander S Pasciak; Austin C Bourgeois; Yong C Bradley
Journal:  Front Oncol       Date:  2014-05-22       Impact factor: 6.244

Review 8.  Current Status of Radiopharmaceutical Therapy.

Authors:  Sara St James; Bryan Bednarz; Stanley Benedict; Jeffrey C Buchsbaum; Yuni Dewaraja; Eric Frey; Robert Hobbs; Joseph Grudzinski; Emilie Roncali; George Sgouros; Jacek Capala; Ying Xiao
Journal:  Int J Radiat Oncol Biol Phys       Date:  2020-08-14       Impact factor: 7.038

9.  Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy.

Authors:  Justin K Mikell; Armeen Mahvash; Wendy Siman; Firas Mourtada; S Cheenu Kappadath
Journal:  EJNMMI Phys       Date:  2015-07-30

Review 10.  Radioembolization and the Dynamic Role of (90)Y PET/CT.

Authors:  Alexander S Pasciak; Austin C Bourgeois; J Mark McKinney; Ted T Chang; Dustin R Osborne; Shelley N Acuff; Yong C Bradley
Journal:  Front Oncol       Date:  2014-02-27       Impact factor: 6.244

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.