Literature DB >> 22214683

Assessment of bone microcirculation by contrast-enhanced ultrasound (CEUS) and [18F]-positron emission tomography/computed tomography in free osseous and osseocutaneus flaps for mandibular reconstruction: preliminary results.

S Müller1, M Gosau, D Strobel, S Gehmert, A Moralis, T E Reichert, L Prantl, E M Jung.   

Abstract

PURPOSE: Postsurgical evaluation of bone microcirculation in osseous and osseocutaneus free flaps by contrast enhanced ultrasound (CEUS) with time intensity curve (TIC) analysis and [18F]-positron emission tomography/computed tomography (Fluoride-PET/CT). PATIENTS AND METHODS: 10 patients with osseous or osseocutaneus microvascular flaps were evaluated with CEUS. Ultrasound was carried out by an experienced examiner with a high resolution linear probe (6-9 MHz, LOGIQ E9, GE) after intravenous bolus injection of 2.4 ml SonoVue® (BRACCO, Germany). Time intensity curves (TIC) in selected regions of interest (ROI) were analyzed and compared with the evaluation of [18F]-positron emission tomography/computed tomography and the clinical course for at least 2 month.
RESULTS: 9/10 patients showed evidence for soft tissue and osseous microcirculation of the transplants in CEUS correlating with the clinical course. The soft tissue parts of the transplant showed a mean value of 84% (range 51-98%) and the bone parts a mean value of 39% (range 11-75%) for the Area under the curve (AuC) compared with the AuC for the anastomotic vessel region. Mean values for time to peak (TTP) were 27,1 sec (range 8.7-52.0 sec) for the anastomotic vessels, 29.3 sec (range 7.9-62.0 sec) for the soft tissue of and 32.0 sec (range 7.4-69.0 sec) for the transplant bone. In 1/10 patients flap failure occurred, after denudation the bone was left as an avascular transplant. AuC showed a mean value of 0.5 % for the bone region compared with the vessel region. Fluoride-PET/CT assessed bone vitality in 7 patients as "good" in 1 patient as "uncertain" and in 1 patient as "poor". CEUS assessment was corresponding with Fluoride-PET/CT in 4 patients, clinical assessment in 6 patients.
CONCLUSION: Fluoride-PET/CT is a valuable tool to make an indirect statement about the perfusion of the transplanted bone and was used as control in this study. CEUS is a new and promising method for the evaluation of microcirculation of buried free microvascular bone grafts and the osseous part of osseocutaneous flaps and may be used for a steady monitoring in the first postoperative days.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22214683     DOI: 10.3233/CH-2011-1462

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  4 in total

1.  Sodium 18F-fluoride PET/CT of bone, joint, and other disorders.

Authors:  Hossein Jadvar; Bhushan Desai; Peter S Conti
Journal:  Semin Nucl Med       Date:  2015-01       Impact factor: 4.446

2.  Endosteal and periosteal blood flow quantified with dynamic contrast-enhanced fluorescence to guide open orthopaedic surgery.

Authors:  Shudong Jiang; Jonathan T Elliott; Jason R Gunn; Cao Xu; Alberto J Ruiz; Eric R Henderson; Brian W Pogue; I Leah Gitajn
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-02-19

3.  Blood perfusion in osteomyelitis studied with [15O]water PET in a juvenile porcine model.

Authors:  Lars Jødal; Ole L Nielsen; Pia Afzelius; Aage K O Alstrup; Søren B Hansen
Journal:  EJNMMI Res       Date:  2017-01-14       Impact factor: 3.138

4.  Bone Fragment Co-transplantation Alongside Bone Marrow Aspirate Infusion Protects Kidney Transplant Recipients.

Authors:  Xianzhang Luo; Ji Zhang; Sijuan Zou; Xinqiang Wang; Gen Chen; Zhen Li; Kaiyan Li; Mengqing Wang; Zhishui Chen; Changshen Ming; Xiaohua Zhu; Nianqiao Gong
Journal:  Front Immunol       Date:  2021-02-11       Impact factor: 7.561

  4 in total