Abstract

PURPOSE: To evaluate whether the image fusion with contrast enhanced ultrasound (CEUS) and CT affects the diagnosis of endoleaks in unclear cases. METHODS AND MATERIALS: 35 patients with follow-up examinations after endovascular aneurysm repair (EVAR) were included in this retrospective study. Mean patient age was 73 years (range 54-83 y). B-scan, colour doppler and CEUS (1.2 ml SonoVue®, Bracco Imaging Germany) were performed in all patients by an experienced examiner using two different high-end ultrasound system (Siemens ACUSON S2000™, Siemens Healthcare, Erlangen, Germany or Logic E9, GE Healthcare, Milwaukee,WI, USA) with a multifrequency curved array transducer. The examiner was initially blinded to the CT results. Additional image fusion with CT-angiography (CTA) was then performed. The ultrasound examinations were later read by two blinded unbiased investigators with more than five years of clinical ultrasound in consensus.
RESULTS: All patients were examined using all diagnostic ultrasound tools of the study. The results show that image fusion is easy and convenient to perform. Conventional ultrasound examination with B-scan and colour Doppler examination detected one Type I and one Type II endoleak, contrast enhanced ultrasound detected one Type I and three Type II endoleaks after EVAR whereas CTA depicted one Type I and two Type II endoleaks. Ultrasound image fusion with CT-angiography confirmed one Type I and three Type II endoleaks.
CONCLUSION: In comparison to conventional ultrasound and CTA the use of CEUS improved the visualization and classification of endoleaks. CEUS shows even small blood flow which can be depicted due to the real time imaging of endoleaks. In unclear cases additional ultrasound image fusion with CEUS and CT angiography improves the visualisation of small endoleaks and this may cause a change in the follow-up interval. CEUS is a good alternative to CT in the detection and follow-up of endoleaks, especially in patients with contraindications to CT contrast agents due to allergies or renal failure, enabling reduced additional costs and exposure to radiation.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22214681     DOI: 10.3233/CH-2011-1460

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  8 in total

Review 1.  [Possibilities of sonographic image fusion: Current developments].

Authors:  E M Jung; D-A Clevert
Journal:  Radiologe       Date:  2015-11       Impact factor: 0.635

Review 2.  [Sonographic imaging of the prostate].

Authors:  B Schlenker; D A Clevert; G Salomon
Journal:  Urologe A       Date:  2014-07       Impact factor: 0.639

3.  [Ultrasound-guided image fusion with computed tomography and magnetic resonance imaging. Clinical utility for imaging and interventional diagnostics of hepatic lesions].

Authors:  D-A Clevert; A Helck; P M Paprottka; P Zengel; C Trumm; M F Reiser
Journal:  Radiologe       Date:  2012-01       Impact factor: 0.635

4.  Is contrast-enhanced ultrasound (CEUS) superior to computed tomography angiography (CTA) in detection of endoleaks in post-EVAR patients? A systematic review and meta-analysis.

Authors:  Amer Harky; Ewa Zywicka; Giovanni Santoro; Lucas Jullian; Mihika Joshi; Sameh Dimitri
Journal:  J Ultrasound       Date:  2019-02-15

Review 5.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09

Review 6.  Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis.

Authors:  Georgios I Karaolanis; Constantine N Antonopoulos; Efstratios Georgakarakos; Georgios D Lianos; Michail Mitsis; Georgios K Glantzounis; Athanasios Giannoukas; George Kouvelos
Journal:  J Clin Med       Date:  2022-06-23       Impact factor: 4.964

7.  Initial experience with Duplex scan combined with contrast-enhanced ultrasound for follow-up of endovascular abdominal aortic aneurysm repair.

Authors:  Carolina Brito Faustino; Carlos Ventura; Maria Fernanda Cassino Portugal; André Brunheroto; Marcelo Passos Teivelis; Nelson Wolosker
Journal:  J Vasc Bras       Date:  2021-11-01

Review 8.  Diagnostic vascular ultrasonography with the help of color Doppler and contrast-enhanced ultrasonography.

Authors:  Johannes Rübenthaler; Maximilian Reiser; Dirk-André Clevert
Journal:  Ultrasonography       Date:  2016-08-12
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.