Literature DB >> 22213517

Distortion correction in EPI at ultra-high-field MRI using PSF mapping with optimal combination of shift detection dimension.

Se-Hong Oh1, Jun-Young Chung, Myung-Ho In, Maxim Zaitsev, Young-Bo Kim, Oliver Speck, Zang-Hee Cho.   

Abstract

Despite its wide use, echo-planar imaging (EPI) suffers from geometric distortions due to off-resonance effects, i.e., strong magnetic field inhomogeneity and susceptibility. This article reports a novel method for correcting the distortions observed in EPI acquired at ultra-high-field such as 7 T. Point spread function (PSF) mapping methods have been proposed for correcting the distortions in EPI. The PSF shift map can be derived either along the nondistorted or the distorted coordinates. Along the nondistorted coordinates more information about compressed areas is present but it is prone to PSF-ghosting artifacts induced by large k-space shift in PSF encoding direction. In contrast, shift maps along the distorted coordinates contain more information in stretched areas and are more robust against PSF-ghosting. In ultra-high-field MRI, an EPI contains both compressed and stretched regions depending on the B0 field inhomogeneity and local susceptibility. In this study, we present a new geometric distortion correction scheme, which selectively applies the shift map with more information content. We propose a PSF-ghost elimination method to generate an artifact-free pixel shift map along nondistorted coordinates. The proposed method can correct the effects of the local magnetic field inhomogeneity induced by the susceptibility effects along with the PSF-ghost artifact cancellation. We have experimentally demonstrated the advantages of the proposed method in EPI data acquisitions in phantom and human brain using 7-T MRI.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22213517     DOI: 10.1002/mrm.23317

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  A high-resolution 7-Tesla fMRI dataset from complex natural stimulation with an audio movie.

Authors:  Michael Hanke; Florian J Baumgartner; Pierre Ibe; Falko R Kaule; Stefan Pollmann; Oliver Speck; Wolf Zinke; Jörg Stadler
Journal:  Sci Data       Date:  2014-05-27       Impact factor: 6.444

2.  Super-resolution track-density imaging of thalamic substructures: comparison with high-resolution anatomical magnetic resonance imaging at 7.0T.

Authors:  Fernando Calamante; Se-Hong Oh; Jacques-Donald Tournier; Sung-Yeon Park; Young-Don Son; Jun-Young Chung; Je-Geun Chi; Graeme D Jackson; Chan-Woong Park; Young-Bo Kim; Alan Connelly; Zang-Hee Cho
Journal:  Hum Brain Mapp       Date:  2012-11-14       Impact factor: 5.038

3.  Distortion correction of echo planar images applying the concept of finite rate of innovation to point spread function mapping (FRIP).

Authors:  Rita G Nunes; Joseph V Hajnal
Journal:  MAGMA       Date:  2018-01-03       Impact factor: 2.310

4.  EPI distortion correction for concurrent human brain stimulation and imaging at 3T.

Authors:  Hyuntaek Oh; Jung Hwan Kim; Jeffrey M Yau
Journal:  J Neurosci Methods       Date:  2019-08-18       Impact factor: 2.390

5.  Evaluation of a novel 8-channel RX coil for speech production MRI at 0.55 T.

Authors:  Felix Muñoz; Yongwan Lim; Sophia X Cui; Helmut Stark; Krishna S Nayak
Journal:  MAGMA       Date:  2022-08-20       Impact factor: 2.533

6.  Highly accelerated Point-Spread Function mapping based on Finite Rate of Innovation for EPI distortion correction.

Authors:  Rita G Nunes; Joseph V Hajnal
Journal:  EJNMMI Phys       Date:  2014-07

7.  Distortion correction in EPI using an extended PSF method with a reversed phase gradient approach.

Authors:  Myung-Ho In; Oleg Posnansky; Erik B Beall; Mark J Lowe; Oliver Speck
Journal:  PLoS One       Date:  2015-02-23       Impact factor: 3.240

8.  The impact of T1 versus EPI spatial normalization templates for fMRI data analyses.

Authors:  Vince D Calhoun; Tor D Wager; Anjali Krishnan; Keri S Rosch; Karen E Seymour; Mary Beth Nebel; Stewart H Mostofsky; Prashanth Nyalakanai; Kent Kiehl
Journal:  Hum Brain Mapp       Date:  2017-07-26       Impact factor: 5.038

9.  Visualization of live, mammalian neurons during Kainate-infusion using magnetic resonance microscopy.

Authors:  Jeremy J Flint; Kannan Menon; Brian Hansen; John Forder; Stephen J Blackband
Journal:  Neuroimage       Date:  2020-05-31       Impact factor: 6.556

10.  MRI measurements of reporter-mediated increases in transmembrane water exchange enable detection of a gene reporter.

Authors:  Franz Schilling; Susana Ros; De-En Hu; Paula D'Santos; Sarah McGuire; Richard Mair; Alan J Wright; Elizabeth Mannion; Robin J M Franklin; André A Neves; Kevin M Brindle
Journal:  Nat Biotechnol       Date:  2016-12-05       Impact factor: 54.908

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.