Literature DB >> 22210013

The use of a transition rod may prevent proximal junctional kyphosis in the thoracic spine after scoliosis surgery: a finite element analysis.

Patrick J Cahill1, Wenhai Wang, Jahangir Asghar, Rashad Booker, Randal R Betz, Christopher Ramsey, George Baran.   

Abstract

STUDY
DESIGN: Finite element analysis.
OBJECTIVE: Via finite element analysis: (1) to demonstrate the abnormal forces present at the top of a scoliosis construct, (2) to demonstrate the importance of an intact interspinous and supraspinous ligament (ISL/SSL) complex, and (3) to evaluate a transition rod (a rod that has a short taper to a smaller diameter at one end) as an implant solution to diminish these pathomechanics, regardless of the integrity of the ISL/SSL complex. SUMMARY OF BACKGROUND DATA: The pathophysiology of increased nucleus pressure and increased angular displacement may contribute to proximal junctional kyphosis. Furthermore, high implant stress can be demonstrated at the upper end of the construct, possibly leading to the risk of implant failure.
METHODS: A finite element model was constructed to simulate a thoracic spinal fusion. The model was altered to remove the ISL/SSL complex at the level above the construct. Then, the model was altered again by extending the construct one level superior with a transition rod. The angular displacement, the maximum pressure in the nucleus, and stress within the implant were extracted from computational results under 2 conditions: load control and displacement control. The testing was performed with both titanium and stainless steel implants.
RESULTS: Pressure in the nucleus and angular displacement are all increased when the ISL/SSL complex is removed immediately above the instrumented levels, whereas the screw pullout force and maximum stress within the screw are decreased. The nucleus pressure increases by more than 50%. The angular displacement increases by 19% to 26%. This absence of the ISL/SSL complex simulates the clinical scenario that occurs when these structures are iatrogenically detached. Abnormal mechanics can be restored to normal level by extending the construct rostral one level with a transition rod. Furthermore, the elevated nucleus pressure and angular displacement noted even when the ISL/SSL complex is intact can be avoided with the use of a transition rod. Under the same bending moment (3 Nm), the nucleus pressure at the level immediately cephalad is up to 23% lower than the pressure in a standard construct. The angular displacement is 18% to 19% less than the standard construct. The maximum implant stress is also decreased by as much as 60%.
CONCLUSION: Finite element modeling suggests that the pathomechanics at the proximal end of a scoliosis construct may be diminished by preserving the ISL/SSL complex and possibly completely eliminated with the use of rods with a diameter transition at the most proximal level.

Entities:  

Mesh:

Year:  2012        PMID: 22210013     DOI: 10.1097/BRS.0b013e318246d4f2

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  21 in total

1.  Supplementary delta-rod configurations provide superior stiffness and reduced rod stress compared to traditional multiple-rod configurations after pedicle subtraction osteotomy: a finite element study.

Authors:  Pedro Berjano; Ming Xu; Marco Damilano; Thomas Scholl; Claudio Lamartina; Michael Jekir; Fabio Galbusera
Journal:  Eur Spine J       Date:  2019-05-25       Impact factor: 3.134

Review 2.  Proximal junctional kyphosis following adult spinal deformity surgery.

Authors:  Samuel K Cho; John I Shin; Yongjung J Kim
Journal:  Eur Spine J       Date:  2014-09-04       Impact factor: 3.134

3.  A novel technique to reduce proximal junctional kyphosis in adults.

Authors:  L Tillotson; O M Stokes; D Chan
Journal:  Ann R Coll Surg Engl       Date:  2017-09       Impact factor: 1.891

Review 4.  Osteoporosis and the Management of Spinal Degenerative Disease (II).

Authors:  Félix Tomé-Bermejo; Angel R Piñera; Luis Alvarez
Journal:  Arch Bone Jt Surg       Date:  2017-11

Review 5.  Junctional spinal disorders in operated adult spinal deformities: present understanding and future perspectives.

Authors:  V Arlet; M Aebi
Journal:  Eur Spine J       Date:  2013-02-06       Impact factor: 3.134

6.  Incidence and risk factors for proximal junctional kyphosis: a meta-analysis.

Authors:  Feng-Yu Liu; Tao Wang; Si-Dong Yang; Hui Wang; Da-Long Yang; Wen-Yuan Ding
Journal:  Eur Spine J       Date:  2016-03-19       Impact factor: 3.134

7.  Prevention of Proximal Junctional Kyphosis & Failure Using Sublaminar Bands in a Hybrid Construct in Pediatric Kyphosis Deformity.

Authors:  Christopher Battista; Christopher Wild; Sarah Kreul; Michael Albert
Journal:  Int J Spine Surg       Date:  2018-12-21

8.  Biomechanical Analysis of the Proximal Adjacent Segment after Multilevel Instrumentation of the Thoracic Spine: Do Hooks Ease the Transition?

Authors:  Melodie F Metzger; Samuel T Robinson; Mark T Svet; John C Liu; Frank L Acosta
Journal:  Global Spine J       Date:  2015-08-21

9.  Incidence and risk factors for the progression of proximal junctional kyphosis in degenerative lumbar scoliosis following long instrumented posterior spinal fusion.

Authors:  Hui Wang; Lei Ma; Dalong Yang; Tao Wang; Sidong Yang; Yanhong Wang; Qian Wang; Feng Zhang; Wenyuan Ding
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

10.  Biomechanical study of rod stress after pedicle subtraction osteotomy versus anterior column reconstruction: A finite element study.

Authors:  Jacob Januszewski; Joshua M Beckman; Jeffrey E Harris; Alexander W Turner; Chun Po Yen; Juan S Uribe
Journal:  Surg Neurol Int       Date:  2017-09-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.