Literature DB >> 22209249

Simultaneous determination of Cr(III) and Cr(VI) in tannery wastewater using low pressure ion chromatography combined with flow injection spectrophotometry.

Shujuan Chen1, Xinshen Zhang, Lingyun Yu, Li Wang, Hui Li.   

Abstract

Trivalent and hexavalent chromium have been successfully separated and determined using low pressure ion chromatography combined with flow injection spectrophotometric analysis (LPIC-FIA). A column packed with crosslinking starch microspheres was used for on-line separation of Cr(III) from Cr(VI) in a flow-injection system because of its absorptive effect on Cr(III). To determine the concentration of Cr(III) and Cr(VI) in samples, we used 3.0 mmol/L nitric acid to elute adsorbed Cr(III) from the column and then used ceric sulfate-sulfuric acid as oxidant to convert all Cr(III) into Cr(VI). Then, Cr(VI) directly came from the samples and Cr(VI) came from Cr(III) successively formed a amaranthine complex with diphenycarbazide and the complex shows a maximum absorption at 530 nm. Analytical parameters including the concentration of eluent and oxidant solution, oxidizing temperature, length of oxidizing reaction coil, reaction coil and injection coil, interfering effects, etc., were optimized. The limit of detection was 1.25 μg/L for Cr(VI) and 3.76 μg/L for Cr(III). The linear relationship between absorption with the concentration of Cr(VI) and Cr(III) was 0.001-1.000 mg/L and 0.030-1.000 mg/L with correlation coefficients of 0.9995 and 0.9994, respectively. The relative standard deviation of Cr(VI) and Cr(III) was 1.21% and 1.66%, respectively (n=10). Major cations and anions did not show any interference. We validated this method through certified reference materials and through measuring the recovery in tannery wastewater.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22209249     DOI: 10.1016/j.saa.2011.11.053

Source DB:  PubMed          Journal:  Spectrochim Acta A Mol Biomol Spectrosc        ISSN: 1386-1425            Impact factor:   4.098


  3 in total

1.  Inner-filter Effect Induced Fluorescence Quenching of Carbon Dots for Cr(VI) Detection with High Sensitivity.

Authors:  Tao Liu; Shuai Zhang; Xiaoyu Fan; Dou Yang; Min Wang; Xiaodong Shao; Shuhao Wang; Qiaoli Yue
Journal:  J Fluoresc       Date:  2022-09-26       Impact factor: 2.525

2.  A Label-Free Fluorescent Sensor Based on Si,N-Codoped Carbon Quantum Dots with Enhanced Sensitivity for the Determination of Cr(VI).

Authors:  Jinyu Zhang; Cai Jing; Binsong Wang
Journal:  Materials (Basel)       Date:  2022-02-25       Impact factor: 3.623

3.  Vortex-assisted liquid-liquid microextraction and indirect spectrophotometric determination of chromium(vi).

Authors:  Yaroslav Bazel; Tetiana Riabukhina
Journal:  RSC Adv       Date:  2018-10-15       Impact factor: 3.361

  3 in total