Safety and effectiveness of the Catania Polyzene-F coated stent in real world clinical practice: 12-month results from the ATLANTA 2 registry.

Corrado Tamburino1, Davide Capodanno, Maria Elena Di Salvo, Alessandra Sanfilippo, Irene Cascone, Valentina Incardona, Giovanni Longo, Daniele Giacoppo, Piera Capranzano, Carmelo Sgroi, Gianpaolo Ussia, Alfio Monaco, Alessio La Manna.   

Abstract

AIMS: The pivotal ATLANTA first-in-man study showed the promising safety and efficacy profile of the novel Catania™ stent in a population with ~20% American College of Cardiology/American Heart Association (ACC/AHA) type C coronary lesions. The ATLANTA 2 registry was designed to evaluate the 12-month safety and efficacy of the Catania stent in a broader real world scenario. METHODS AND
RESULTS: The ATLANTA 2 registry was a prospective, non-randomised, single-arm study of patients with symptomatic ischaemic heart disease and de novo lesions of native coronary arteries. A total of 300 patients (396 lesions) were recruited and 482 Catania stents were implanted. At 12 months, major adverse cardiac events were 8.8%, mainly driven by target lesion revascularisation (6.5%). Cardiac death and non-fatal myocardial infarction occurred in 2.5% and 0.7% of patients, respectively. Subacute definite or probable stent thrombosis was 0.7%. No late stent thrombosis was recorded. Compared with patients treated with drug-eluting stents or bare metal stents in the study period, those treated with Catania stents experienced similar outcomes at one year.
CONCLUSIONS: The 12-month results of the ATLANTA 2 registry confirmed the positive results of the ATLANTA first-in-man trial in a more complex population. A randomised trial is needed to assess the comparative value of the Catania stent over currently-used drug-eluting stents or bare metal stents.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22207230     DOI: 10.4244/EIJV7I9A169

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  2 in total

1.  Undesired Outcomes of the Catania Stent Compared to the Xience Stent in Patients Undergoing Angioplasty: A Double-Blind Randomized Controlled Trial.

Authors:  Masoud Pourmoghaddas; Hamid Reza Rohani; Hamid Sanei; Afshin Amirpour
Journal:  Adv Biomed Res       Date:  2017-11-30

Review 2.  COBRA PzF™ coronary stent in clinical and preclinical studies: setting the stage for new antithrombotic strategies?

Authors:  Anne Cornelissen; Atsushi Sakamoto; Yu Sato; Rika Kawakami; Masayuki Mori; Kenji Kawai; Matthew Kutyna; Raquel Fernandez; Saikat Ghosh; Mark Barakat; Renu Virmani; Aloke Finn
Journal:  Future Cardiol       Date:  2021-09-15
  2 in total