Literature DB >> 22205833

Iritis and iris atrophy after eyebrow epilation with alexandrite laser.

Zachary Elkin1, Milan P Ranka, Eleanore T Kim, Ronit Kahanowicz, Wayne G Whitmore.   

Abstract

PURPOSE: To report a case of bilateral iritis and transillumination defects after laser hair removal of the eyebrows with an alexandrite laser.
METHODS: A 41-year-old male presented with bilateral eye pain and mild photophobia 2 days after receiving alexandrite (755 nm) laser epilation of both eyebrows. Examination showed visual acuity of 20/20 in both eyes, 2+ conjunctival injection in both eyes, 1+ cells in the anterior chamber of right eye and trace cells in left eye, poor right pupil dilation, and left pupil without movement. Intraocular pressure and fundus examination were normal. He was diagnosed with iritis and iris atrophy, associated with laser epilation. Topical steroids and cycloplegic drops were prescribed for 1 month.
RESULTS: After 1 month of treatment, transillumination defects remained in both eyes, but greater in right. In dim light, the right pupil was 4 mm and oval and the left pupil was 6 mm and round. Visual acuity remained 20/20 in both eyes.
CONCLUSION: Laser hair removal of the eyebrows can lead to permanent ocular damage even with eye protection, and should be avoided.

Entities:  

Keywords:  alexandrite laser; laser hair removal; transillumination defects

Year:  2011        PMID: 22205833      PMCID: PMC3245195          DOI: 10.2147/OPTH.S26035

Source DB:  PubMed          Journal:  Clin Ophthalmol        ISSN: 1177-5467


Introduction

Laser hair epilation remains one of the most popular and effective treatments for long-term removal of unwanted hair. With multiple treatments, hair reduction of 74%–84% can be seen at 18 months.1 Epilation lasers include red spectrum ruby (694 nm), near infrared spectrum alexandrite (755 nm), diode (800–810 nm), neodymium: yttrium-aluminum garnet (1064 nm), and intense pulse light (590–1200 nm). While nonophthalmologic complications of laser epilation have been extensively described in the literature, there are only a few case reports of ocular complications with laser epilation of the eyebrows.2–7 Most case reports occurred with the diode (810 nm) laser in female patients. The female patients previously described presented between 1 day and 1 week with pain, redness, photophobia, and blurred vision. Examinations were significant for iris atrophy, anterior chamber reactions, posterior synechiae, and abnormal dilation. Herbold et al described a case of bilateral pigment dispersion and anterior subcapular cataracts in a 27-year-old female following epilation with a diode laser.3 In previous cases, the observed iritis appeared to improve after 1–5 weeks of topical steroids, but the iris atrophy remained. Carrim et al was the only group to describe a case with the less penetrating alexandrite laser, leading to acute anterior uveitis, pigment dispersion with secondary increased intraocular pressure, and transillumination defects.4 This report describes a new case of a male patient with iritis and iris atrophy after receiving laser epilation of the eyebrows with an alexandrite (755 nm) laser while not wearing protective eyewear.

Case report

A 41-year-old Caucasian male with hypertension and no significant past ocular history, specifically no history of uveitis, presented with bilateral eye pain and mild photophobia 2 days after receiving alexandrite (755 nm) laser epilation of both eyebrows. While the patient was at an appointment for laser epilation of his back, he asked that the laser be used on his eyebrows as well. He reported that he closed his eyes and covered them with his fingers during the treatment. He did not wear any protective eyewear. Shortly after the treatment, the patient had pain and redness in both eyes, without change in vision. The patient presented 2 days later with worsening pain, redness, and photophobia. Visual acuity was 20/20 in both eyes. The examination was significant for 2+ conjunctival injection bilaterally, 1+ cells in the anterior chamber of the right eye, and trace cells in the left eye. Intraocular pressure was within normal limits. There was corectopia of the right pupil with poor dilation of the temporal side. The left pupil was round without movement. No synechiae were appreciated. Fundus examination was within normal limits. The patient was started on topical steroids for his iritis and cycloplegic drops for the atonic pupils. One week later, the right eye still had an anterior chamber reaction with an irregular (4.0 × 4.5 mm) pupil. The left eye was quiet with a round pupil, dilating to 5.5 mm. At his 2-week follow-up, both eyes were quiet, however multiple transillumination defects were noted in both eyes ( Figures 1 and 2). Medications were tapered. At 1 month, visual acuity remained 20/20 in both eyes. In bright light, both pupils were 3 mm and round. In dim light, the right pupil was 4 mm and oval and the left pupil was 6 mm and round. Ocular tensions and fundus examination remained normal.
Figure 1

Transillumination defects of the right eye at 2 weeks.

Figure 2

Transillumination defects of the left eye at 2 weeks.

Discussion

Laser epilation uses selective photothermolysis to remove unwanted hair. The red and near infrared wavelengths of the lasers penetrate into the dermis, where they are absorbed by melanin in hair follicles.1 The light is pulsed at a fast enough frequency to damage the hair follicles without transmitting energy to the surrounding tissue. Surrounding pigmented tissues, however, compete for the energy leading to the common side effects of pain, erythema, and skin pigment changes. In particular, alexandrite and diode lasers, which differ by wavelength, were designed for deeper penetration of the skin to prevent these side effects in patients with darker skin. When used on the superficial coarse hair of the eyebrow, these lasers risk penetrating the thin skin of the eyelid and damaging the pigmented structures of the eye. In the clinic where this patient received his laser hair removal, the spot size used for the alexandrite laser is 8–12 mm, which allows for a minimum penetration of 2–3 mm. As described in previous reports, the normal Bell’s phenomenon of upgaze with closed eyes will align the pigmented iris with the peripheral beams of the laser.2 As evident by the normal fundus examinations, the laser did not appear to penetrate deep enough to damage the pigmented retina. Notable in most of the cases is the lack of protective eyewear during the laser treatment. Safety goggles, however, were reportedly used in two of the cases.5,6 There was no mention of the use of metal shields as eye protection for these procedures or whether metal shields would provide better protection. Furthermore, the iris trauma in this case was due to penetrated and not scattered, reflected, or misdirected laser energy. Therefore, protective goggles over the eyes would not have prevented damage since the laser was pointed at hair with the eye directly underneath. This hair and skin had to be exposed for the desired hair removal. The importance of this case report is to illustrate that ocular damage can occur with the less penetrating alexandrite laser and continues to occur despite published reports. Given these permanent ocular complications, even with protective eyewear, the use of laser hair removal of the eyebrows is dangerous and should not be performed. If this method is to be chosen, physicians, technicians, and patients should be more educated about the specific ocular complications that can occur.
  7 in total

1.  Iris damage and acute pigment dispersion following photo-epilation.

Authors:  Z I Carrim; A W Chohan; H C Devlin
Journal:  Eye (Lond)       Date:  2006-05-05       Impact factor: 3.775

2.  Iris atrophy and posterior synechiae as a complication of eyebrow laser epilation.

Authors:  Ioannis Halkiadakis; Sotiris Skouriotis; Christina Stefanaki; Eleni Patsea; Dimitrios Papakonstatndinou; Apostolos Amariotakis; Gerasimos T Georgopoulos
Journal:  J Am Acad Dermatol       Date:  2007-08       Impact factor: 11.527

3.  Bilateral cataract and corectopia after laser eyebrow [corrected] epilation.

Authors:  Tobias M Herbold; Holger Busse; Constantin E Uhlig
Journal:  Ophthalmology       Date:  2005-09       Impact factor: 12.079

4.  Best practice options for hair removal in patients with unwanted facial hair using combination therapy with laser: guidelines drawn up by an expert working group.

Authors:  M Lapidoth; C Dierickx; S Lanigan; U Paasch; A Campo-Voegeli; S Dahan; L Marini; M Adatto
Journal:  Dermatology       Date:  2010-06-26       Impact factor: 5.366

5.  Ocular complications of laser-assisted eyebrow epilation.

Authors:  S Shulman; I Bichler
Journal:  Eye (Lond)       Date:  2009-02-13       Impact factor: 3.775

6.  Diode-laser-induced cataract and iris atrophy as a complication of eyelid hair removal.

Authors:  Harilaos S Brilakis; Edward J Holland
Journal:  Am J Ophthalmol       Date:  2004-04       Impact factor: 5.258

7.  Diode laser-induced uveitis and visual field defect.

Authors:  Amber Sheikh; William Hodge; Stuart Coupland
Journal:  Ophthalmic Plast Reconstr Surg       Date:  2007 Jul-Aug       Impact factor: 1.746

  7 in total
  4 in total

1.  Anterior uveitis following eyebrow epilation with alexandrite laser.

Authors:  Yunus Karabela; Mustafa Eliaçık
Journal:  Int Med Case Rep J       Date:  2015-09-07

2.  Anterior uveitis associated with laser epilation of eyebrows.

Authors:  Fatime Nilüfer Yalçındağ; Aslıhan Uzun
Journal:  J Ophthalmic Inflamm Infect       Date:  2013-04-15

3.  Use of an Intravitreal Dexamethasone Implant (Ozurdex) in a Case with Accidental Foveal Photocoagulation by Alexandrite Laser.

Authors:  Muhammed Nurullah Bulut; Ümit Çallı; Eren Göktaş; Kezban Bulut; Baran Kandemir; Yusuf Özertürk
Journal:  Case Rep Ophthalmol       Date:  2016-02-26

4.  Alexandrite laser induced uveitis & pigment dispersion: A case report and review of the literature.

Authors:  Eric L Crowell; Henry Jampel; Meghan Berkenstock
Journal:  Am J Ophthalmol Case Rep       Date:  2020-03-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.