In-vitro recording of forward light-scatter by human lens capsules and different types of posterior capsule opacification.

Maartje C J van Bree1, Ivanka J E van der Meulen, Luuk Franssen, Joris E Coppens, Bart L M Zijlmans, Thomas J T P van den Berg.   

Abstract

The purpose of the present study was to elucidate the effect of posterior capsule opacification (PCO) on the straylight domain of visual function. PCO is heterogeneous with regard to morphology and severity; both aspects contribute to its functional effect. The isolated impact of capsule areas with specific morphology and severity on straylight was studied in-vitro by recording forward light-scatter. Forward light-scatter by four different capsule types, i.c. anterior capsule (AC), clear posterior capsule (PC), fibrotic and regeneratory PCO, was recorded at several visual angles with a goniometer, using different wavelengths. Angular (θ(a)) and wavelength dependencies (λ(b)) were studied by determining exponents a and b. Recorded straylight values of isolated capsule areas varied between 10× below to 10× above the value normal for the human eye, depending on the capsule's condition (clear to opacified). The angular dependence of light scattered by clear PCs was weaker, whereas in the other capsule types it was stronger than in the normal eye. On average, the wavelength dependence of light scattered by different capsule types was similar, but the variation was considerable. At the smallest visual angles, increased angular and decreased wavelength dependence was found, especially in fibrotic and regeneratory PCO. It was concluded that the range of straylight values found in-vitro in lens capsules properly corresponded to that found previously in in-vivo pseudophakics. Surprisingly, the wavelength dependence of PCO indicated that small-particle light-scattering is important in PCO. Refractile effects were more important at small visual angles, as indicated by the combined stronger angular and weaker wavelength dependence. Crown Copyright Â
© 2011. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22197751     DOI: 10.1016/j.exer.2011.12.008

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  3 in total

1.  Effect of anterior capsule polish on visual function: A meta-analysis.

Authors:  Meng-Yao Han; Ai-Hua Yu; Jing Yuan; Xiao-Jun Cai; Jiang-Bo Ren
Journal:  PLoS One       Date:  2019-01-08       Impact factor: 3.240

2.  Posterior capsular opacification comparison between morphology and objective visual function.

Authors:  Chengzhe Lu; Shasha Yu; Hui Song; Yun Zhao; Shiyong Xie; Xin Tang; Xiaoyong Yuan
Journal:  BMC Ophthalmol       Date:  2019-02-04       Impact factor: 2.209

3.  Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique.

Authors:  Abu-Bakar Zafar; Richard C Chu; Miranda N Bishara; Mujtaba A Qazi; Ashraf M Mahmoud; Jay S Pepose
Journal:  Clin Ophthalmol       Date:  2020-05-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.