Literature DB >> 22194020

ECG signal analysis for the assessment of sleep-disordered breathing and sleep pattern.

K Kesper1, S Canisius, T Penzel, T Ploch, W Cassel.   

Abstract

The diagnosis of sleep-disordered breathing (SDB) usually relies on the analysis of complex polysomnographic measurements performed in specialized sleep centers. Automatic signal analysis is a promising approach to reduce the diagnostic effort. This paper addresses SDB and sleep assessment solely based on the analysis of a single-channel ECG recorded overnight by a set of signal analysis modules. The methodology of QRS detection, SDB analysis, calculation of ECG-derived respiration curves, and estimation of a sleep pattern is described in detail. SDB analysis detects specific cyclical variations of the heart rate by correlation analysis of a signal pattern and the heart rate curve. It was tested with 35 SDB-annotated ECGs from the Apnea-ECG Database, and achieved a diagnostic accuracy of 80.5%. To estimate sleep pattern, spectral parameters of the heart rate are used as stage classifiers. The reliability of the algorithm was tested with 18 ECGs extracted from visually scored polysomnographies of the SIESTA database; 57.7% of all 30 s epochs were correctly assigned by the algorithm. Although promising, these results underline the need for further testing in larger patient groups with different underlying diseases.

Entities:  

Mesh:

Year:  2011        PMID: 22194020     DOI: 10.1007/s11517-011-0853-9

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  28 in total

1.  PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals.

Authors:  A L Goldberger; L A Amaral; L Glass; J M Hausdorff; P C Ivanov; R G Mark; J E Mietus; G B Moody; C K Peng; H E Stanley
Journal:  Circulation       Date:  2000-06-13       Impact factor: 29.690

2.  Experimental evidence for phase synchronization transitions in the human cardiorespiratory system.

Authors:  Ronny Bartsch; Jan W Kantelhardt; Thomas Penzel; Shlomo Havlin
Journal:  Phys Rev Lett       Date:  2007-02-01       Impact factor: 9.161

3.  Automatic screening of obstructive sleep apnea from the ECG based on empirical mode decomposition and wavelet analysis.

Authors:  M O Mendez; J Corthout; S Van Huffel; M Matteucci; T Penzel; S Cerutti; A M Bianchi
Journal:  Physiol Meas       Date:  2010-01-20       Impact factor: 2.833

4.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology.

Authors: 
Journal:  Eur Heart J       Date:  1996-03       Impact factor: 29.983

5.  Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation.

Authors:  I Daskalov; I Christov
Journal:  Med Eng Phys       Date:  1997-06       Impact factor: 2.242

6.  Sleep apnea monitoring and diagnosis based on pulse oximetry and tracheal sound signals.

Authors:  Azadeh Yadollahi; Eleni Giannouli; Zahra Moussavi
Journal:  Med Biol Eng Comput       Date:  2010-08-24       Impact factor: 2.602

7.  Meta-analysis of quantitative sleep parameters from childhood to old age in healthy individuals: developing normative sleep values across the human lifespan.

Authors:  Maurice M Ohayon; Mary A Carskadon; Christian Guilleminault; Michael V Vitiello
Journal:  Sleep       Date:  2004-11-01       Impact factor: 5.849

8.  Cyclical variation of the heart rate in sleep apnoea syndrome. Mechanisms, and usefulness of 24 h electrocardiography as a screening technique.

Authors:  C Guilleminault; S Connolly; R Winkle; K Melvin; A Tilkian
Journal:  Lancet       Date:  1984-01-21       Impact factor: 79.321

9.  MESAM: a heart rate and snoring recorder for detection of obstructive sleep apnea.

Authors:  T Penzel; G Amend; K Meinzer; J H Peter; P von Wichert
Journal:  Sleep       Date:  1990-04       Impact factor: 5.849

10.  Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnoea.

Authors:  Philip de Chazal; Conor Heneghan; Elaine Sheridan; Richard Reilly; Philip Nolan; Mark O'Malley
Journal:  IEEE Trans Biomed Eng       Date:  2003-06       Impact factor: 4.538

View more
  7 in total

1.  All night analysis of time interval between snores in subjects with sleep apnea hypopnea syndrome.

Authors:  J Mesquita; J Solà-Soler; J A Fiz; J Morera; R Jané
Journal:  Med Biol Eng Comput       Date:  2012-03-10       Impact factor: 2.602

2.  Assessment of respiratory flow cycle morphology in patients with chronic heart failure.

Authors:  Ainara Garde; Leif Sörnmo; Pablo Laguna; Raimon Jané; Salvador Benito; Antoni Bayés-Genís; Beatriz F Giraldo
Journal:  Med Biol Eng Comput       Date:  2016-04-23       Impact factor: 2.602

Review 3.  Automatic sleep staging by cardiorespiratory signals: a systematic review.

Authors:  Farideh Ebrahimi; Iman Alizadeh
Journal:  Sleep Breath       Date:  2021-07-29       Impact factor: 2.816

4.  Heart Rate Variability Monitoring during Sleep Based on Capacitively Coupled Textile Electrodes on a Bed.

Authors:  Hong Ji Lee; Su Hwan Hwang; Hee Nam Yoon; Won Kyu Lee; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2015-05-14       Impact factor: 3.576

5.  Development and Test of a Portable ECG Device with Dry Capacitive Electrodes and Driven Right Leg Circuit.

Authors:  Alessandro Zompanti; Anna Sabatini; Simone Grasso; Giorgio Pennazza; Giuseppe Ferri; Gianluca Barile; Massimo Chello; Mario Lusini; Marco Santonico
Journal:  Sensors (Basel)       Date:  2021-04-15       Impact factor: 3.576

6.  Multi-Scale Evaluation of Sleep Quality Based on Motion Signal from Unobtrusive Device.

Authors:  Davide Coluzzi; Giuseppe Baselli; Anna Maria Bianchi; Guillermina Guerrero-Mora; Juha M Kortelainen; Mirja L Tenhunen; Martin O Mendez
Journal:  Sensors (Basel)       Date:  2022-07-15       Impact factor: 3.847

7.  An Energy-Efficient Algorithm for Wearable Electrocardiogram Signal Processing in Ubiquitous Healthcare Applications.

Authors:  Ali Hassan Sodhro; Arun Kumar Sangaiah; Gul Hassan Sodhro; Sonia Lohano; Sandeep Pirbhulal
Journal:  Sensors (Basel)       Date:  2018-03-20       Impact factor: 3.576

  7 in total