OBJECTIVES: The PRELUDE (PRogrammed ELectrical stimUlation preDictive valuE) prospective registry was designed to assess the predictive accuracy of sustained ventricular tachycardia/ventricular fibrillation (VTs/VF) inducibility and to identify additional predictors of arrhythmic events in Brugada syndrome patients without history of VT/VF. BACKGROUND: Brugada syndrome is a genetic disease associated with increased risk of sudden cardiac death. Even though its value has been questioned, inducibility of VTs/VF is widely used to select candidates to receive a prophylactic implantable defibrillator, and its accuracy has never been addressed in prospective studies with homogeneous enrolling criteria. METHODS: Patients with a spontaneous or drug-induced type I electrocardiogram (ECG) and without history of cardiac arrest were enrolled. The registry included 308 consecutive individuals (247 men, 80%; median age 44 years, range 18 to 72 years). Programmed electrical stimulation was performed at enrollment, and patients were followed-up every 6 months. RESULTS: During a median follow-up of 34 months, 14 arrhythmic events (4.5%) occurred (13 appropriate shocks of the implantable defibrillator, and 1 cardiac arrest). Programmed electrical stimulation performed with a uniform and pre-specified protocol induced ventricular tachyarrhythmias in 40% of patients: arrhythmia inducibility was not a predictor of events at follow-up (9 of 14 events occurred in noninducible patients). History of syncope and spontaneous type I ECG (hazard ratio [HR]: 4.20), ventricular refractory period <200 ms (HR: 3.91), and QRS fragmentation (HR: 4.94) were significant predictors of arrhythmias. CONCLUSIONS: Our data show that VT/VF inducibility is unable to identify high-risk patients, whereas the presence of a spontaneous type I ECG, history of syncope, ventricular effective refractory period <200 ms, and QRS fragmentation seem useful to identify candidates for prophylactic implantable cardioverter defibrillator.
OBJECTIVES: The PRELUDE (PRogrammed ELectrical stimUlation preDictive valuE) prospective registry was designed to assess the predictive accuracy of sustained ventricular tachycardia/ventricular fibrillation (VTs/VF) inducibility and to identify additional predictors of arrhythmic events in Brugada syndromepatients without history of VT/VF. BACKGROUND:Brugada syndrome is a genetic disease associated with increased risk of sudden cardiac death. Even though its value has been questioned, inducibility of VTs/VF is widely used to select candidates to receive a prophylactic implantable defibrillator, and its accuracy has never been addressed in prospective studies with homogeneous enrolling criteria. METHODS:Patients with a spontaneous or drug-induced type I electrocardiogram (ECG) and without history of cardiac arrest were enrolled. The registry included 308 consecutive individuals (247 men, 80%; median age 44 years, range 18 to 72 years). Programmed electrical stimulation was performed at enrollment, and patients were followed-up every 6 months. RESULTS: During a median follow-up of 34 months, 14 arrhythmic events (4.5%) occurred (13 appropriate shocks of the implantable defibrillator, and 1 cardiac arrest). Programmed electrical stimulation performed with a uniform and pre-specified protocol induced ventricular tachyarrhythmias in 40% of patients: arrhythmia inducibility was not a predictor of events at follow-up (9 of 14 events occurred in noninducible patients). History of syncope and spontaneous type I ECG (hazard ratio [HR]: 4.20), ventricular refractory period <200 ms (HR: 3.91), and QRS fragmentation (HR: 4.94) were significant predictors of arrhythmias. CONCLUSIONS: Our data show that VT/VF inducibility is unable to identify high-risk patients, whereas the presence of a spontaneous type I ECG, history of syncope, ventricular effective refractory period <200 ms, and QRS fragmentation seem useful to identify candidates for prophylactic implantable cardioverter defibrillator.
Authors: Sergio Dubner; Damián Azocar; Sebastián Gallino; Alfonso Rafael Cerantonio; Sergio Muryan; Juan Medrano; Carlos Bruno Journal: Ann Noninvasive Electrocardiol Date: 2013-05 Impact factor: 1.468
Authors: Adrian Baranchuk; Francisco Femenia; Juan Cruz López-Diez; Claudio Muratore; Mariana Valentino; Enrique Retyk; Nestor Galizio; Darío Di Toro; Karina Alonso; Wilma M Hopman; Rodrigo Miranda Journal: Ann Noninvasive Electrocardiol Date: 2013-09-09 Impact factor: 1.468