Literature DB >> 22192371

A new era of prospective real-world safety evaluation primary report of XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System condition-of-approval post-market study).

Mitchell W Krucoff1, David R Rutledge, Luis Gruberg, Lalitha Jonnavithula, John N Katopodis, William Lombardi, Vivian W Mao, Samin K Sharma, Charles A Simonton, Hoshedar P Tamboli, Jin Wang, Olivia Wilburn, Weiying Zhao, Krishnankutty Sudhir, James B Hermiller.   

Abstract

OBJECTIVES: The XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System Condition-of-Approval Post-Market study) sought to: 1) evaluate the safety of everolimus-eluting coronary stent systems (EECSS) in a contemporary cohort of real-world subjects; and 2) prospectively test the quality of event reporting with analysis of matched patients from the randomized SPIRIT IV (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions) trial.
BACKGROUND: Randomized trials have demonstrated the safety and efficacy of EECSS in selected "standard-risk" patients.
METHODS: The XIENCE V USA trial was a prospective, multicenter, single-arm study in unselected patients. The primary endpoint was Academic Research Consortium (ARC)-defined definite and probable stent thrombosis (ST); the co-primary endpoint was the composite of cardiac death and myocardial infarction at 1 year. Secondary analyses included: 1) stratification by standard-risk and extended-risk cohorts; and 2) late ST after dual antiplatelet therapy interruption.
RESULTS: Of 5,054 participants (1,875 standard-risk; 3,179 extended-risk), 4,958 (98.1%) reached 1-year follow-up. The rate of ARC-defined definite and probable ST was 0.84% (95% confidence interval [CI]: 0.60% to 1.14%) in the overall population and 0.33% (95% CI: 0.12% to 10.72%) and 1.14% (95% CI: 0.80% to 11.58%) in the standard-risk and extended-risk cohorts, respectively. No late ST was observed after dual antiplatelet therapy interruption in either cohort after 6 months. The composite rate of cardiac death and ARC-defined myocardial infarction was 6.5% (95% CI: 5.79% to 17.17%) in the overall population, 3.8% (95% CI: 2.98% to 14.78%) in the standard-risk cohort, and 8.0% (95% CI: 7.09% to 19.02%) in the extended-risk cohort.
CONCLUSIONS: This study comprehensively reports ST rates for EECSS in a contemporary real-world population. The absence of ST after dual antiplatelet therapy interruption beyond 6 months in standard-risk and high-risk patients is notable. Consistent safety outcomes between matched standard-risk cohorts from the XIENCE V USA study and the SPIRIT IV randomized trial suggest that this study affords a reliable benchmark for understanding the safety of EECSS in the context of real-world clinical practice. (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval Study; NCT00676520).
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22192371     DOI: 10.1016/j.jcin.2011.08.010

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  9 in total

1.  One-year clinical outcomes of BioMatrix™-Biolimus A9™ eluting stent: the e-BioMatrix multicenter post marketing surveillance registry in India.

Authors:  Ashwin B Mehta; Praveen Chandra; Jamshed Dalal; Prabhakar Shetty; Devang Desai; K Chocklingam; Jayesh Prajapati; Pramod Kumar; Vilas Magarkar; Apurva Vasawada; B K Goyal; Viveka Kumar; V Suryaprakash Rao; Ramesh Babu; Pritesh Parikh; Upendra Kaul; Aruna Patil; Tushar Mhetre; Hrishikesh Rangnekar
Journal:  Indian Heart J       Date:  2013-09-23

2.  Clinical outcome of biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with diabetes.

Authors:  Ryota Kakizaki; Yoshiyasu Minami; Masahiro Katamine; Aritomo Katsura; Yusuke Muramatsu; Takuya Hashimoto; Kentaro Meguro; Takao Shimohama; Junya Ako
Journal:  Cardiovasc Diabetol       Date:  2020-10-01       Impact factor: 9.951

3.  The resolute™ integrity zotarolimus-eluting stent in coronary artery disease: a review.

Authors:  Subhash Banerjee
Journal:  Cardiol Ther       Date:  2013-01-04

4.  A clinical evaluation of the XIENCE V everolimus eluting stent in the treatment of patients with coronary artery disease: Result from Thailand Registry - XIENCE V performance evaluation (THRIVE study).

Authors:  Songsak Kiatchoosakun; Pavit Pienvichit; Srun Kuanprasert; Navin Suraphakdee; Arintaya Phromminikul
Journal:  Indian Heart J       Date:  2016-10-26

5.  Defining high bleeding risk in patients undergoing percutaneous coronary intervention: a consensus document from the Academic Research Consortium for High Bleeding Risk.

Authors:  Philip Urban; Roxana Mehran; Roisin Colleran; Dominick J Angiolillo; Robert A Byrne; Davide Capodanno; Thomas Cuisset; Donald Cutlip; Pedro Eerdmans; John Eikelboom; Andrew Farb; C Michael Gibson; John Gregson; Michael Haude; Stefan K James; Hyo-Soo Kim; Takeshi Kimura; Akihide Konishi; John Laschinger; Martin B Leon; P F Adrian Magee; Yoshiaki Mitsutake; Darren Mylotte; Stuart Pocock; Matthew J Price; Sunil V Rao; Ernest Spitzer; Norman Stockbridge; Marco Valgimigli; Olivier Varenne; Ute Windhoevel; Robert W Yeh; Mitchell W Krucoff; Marie-Claude Morice
Journal:  Eur Heart J       Date:  2019-08-14       Impact factor: 29.983

Review 6.  Defining High Bleeding Risk in Patients Undergoing Percutaneous Coronary Intervention.

Authors:  Philip Urban; Roxana Mehran; Roisin Colleran; Dominick J Angiolillo; Robert A Byrne; Davide Capodanno; Thomas Cuisset; Donald Cutlip; Pedro Eerdmans; John Eikelboom; Andrew Farb; C Michael Gibson; John Gregson; Michael Haude; Stefan K James; Hyo-Soo Kim; Takeshi Kimura; Akihide Konishi; John Laschinger; Martin B Leon; P F Adrian Magee; Yoshiaki Mitsutake; Darren Mylotte; Stuart Pocock; Matthew J Price; Sunil V Rao; Ernest Spitzer; Norman Stockbridge; Marco Valgimigli; Olivier Varenne; Ute Windhoevel; Robert W Yeh; Mitchell W Krucoff; Marie-Claude Morice
Journal:  Circulation       Date:  2019-05-22       Impact factor: 29.690

7.  Risk factors for coronary drug-eluting stent thrombosis: influence of procedural, patient, lesion, and stent related factors and dual antiplatelet therapy.

Authors:  Krishnankutty Sudhir; James B Hermiller; Joanne M Ferguson; Charles A Simonton
Journal:  ISRN Cardiol       Date:  2013-06-23

8.  Japan-United States of America Harmonized Assessment by Randomized Multicentre Study of OrbusNEich's Combo StEnt (Japan-USA HARMONEE) study: primary results of the pivotal registration study of combined endothelial progenitor cell capture and drug-eluting stent in patients with ischaemic coronary disease and non-ST-elevation acute coronary syndrome.

Authors:  Shigeru Saito; Mitchell W Krucoff; Shigeru Nakamura; Roxana Mehran; Akiko Maehara; Hussein R Al-Khalidi; Stephen M Rowland; Gudaye Tasissa; Debbie Morrell; Diane Joseph; Yumiko Okaniwa; Yoshisato Shibata; Barry D Bertolet; Mark D Rothenberg; Philippe Généreux; Hiram Bezerra; David F Kong
Journal:  Eur Heart J       Date:  2018-07-07       Impact factor: 29.983

9.  Sex-Related Differences in Patients at High Bleeding Risk Undergoing Percutaneous Coronary Intervention: A Patient-Level Pooled Analysis From 4 Postapproval Studies.

Authors:  Rishi Chandiramani; Davide Cao; Bimmer E Claessen; Sabato Sorrentino; Paul Guedeney; Moritz Blum; Ridhima Goel; Anastasios Roumeliotis; Mitchell Krucoff; Ken Kozuma; Junbo Ge; Ashok Seth; Raj Makkar; Sripal Bangalore; Deepak L Bhatt; Dominick J Angiolillo; Karine Ruster; Jin Wang; Shigeru Saito; Franz-Josef Neumann; James Hermiller; Marco Valgimigli; Roxana Mehran
Journal:  J Am Heart Assoc       Date:  2020-03-30       Impact factor: 5.501

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.