Literature DB >> 22192177

Type of interventional pain procedure, body weight, and presence of spinal pathology are determinants of the level of radiation exposure for fluoroscopically guided pain procedures.

Dalvina E Hanu-Cernat1, Rui Duarte, Jon H Raphael, Hirachand Mutagi, Sandeep Kapur, Latha Senthil.   

Abstract

In the recent years new technology has led to the development of a bewildering array of imaging procedures. Yet, conventional radiography remains one of the most used tools to diagnose and to aid procedural interventions. Fluoroscopy guidance facilitates targeted drug delivery or radiofrequency directly to the area of pathology, a benefit that has to be balanced against the risks of radiation exposure. In this prospective observational survey of routine practice, dose area product (DAP) and screening time (ST) were recorded in 127 consecutive patients undergoing fluoroscopically guided spinal procedures along with other probable measures of potentially greater radiation exposure such as weight, type of spinal pathology, the ease of recognition of the anatomical landmarks, and the radiographic quality of the image in terms of contrast and graininess. The mean ST was 34±27 seconds (range, 3 to 218 seconds), the mean DAP was 1.18±1.08 Gy cm(2) (range, 0.023 to 6.82 seconds). A correlation between weight and DAP was confirmed (r=0.230, P<0.05, Spearman's correlation coefficient). Patients with spinal pathology (n=33) had higher radiation exposure than those without (DAP median=0.85, U=978.00, P<0.005, r=-0.28, Mann-Whitney test). The DAP values obtained compare favourably with the recommended doses for radiographs and other procedures, although they generally exceed the values for a chest X-ray.
© 2011 The Authors. Pain Practice © 2011 World Institute of Pain.

Entities:  

Mesh:

Year:  2011        PMID: 22192177     DOI: 10.1111/j.1533-2500.2011.00521.x

Source DB:  PubMed          Journal:  Pain Pract        ISSN: 1530-7085            Impact factor:   3.183


  4 in total

1.  Comparison of radiation exposure during fluoroscopy-guided transforaminal epidural steroid injections at different vertebral levels.

Authors:  Yun Mi Hwang; Min Hee Lee; Seon-Jeong Kim; Sheen-Woo Lee; Hye Won Chung; Sang Hoon Lee; Myung Jin Shin
Journal:  Korean J Radiol       Date:  2015-02-27       Impact factor: 3.500

2.  Factors Related to Radiation Exposure during Lumbar Spine Intervention.

Authors:  Moon Hyung Choi; Byung Gil Choi; Seung Eun Jung; Jae Young Byun
Journal:  J Korean Med Sci       Date:  2016-01-28       Impact factor: 2.153

Review 3.  Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management.

Authors:  Bo Kyung Cheon; Cho Long Kim; Ka Ram Kim; Min Hye Kang; Jeong Ae Lim; Nam Sik Woo; Ka Young Rhee; Hae Kyoung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2018-10-01

4.  Impact of flow pattern, body mass index, and age on intraprocedural fluoroscopic time and radiation dose during sacroiliac joint injections.

Authors:  Christin A Tiegs-Heiden; Naveen S Murthy; Jennifer R Geske; Felix E Diehn; Vance T Lehman; Greta B Liebo; Jared T Verdoorn; Carrie M Carr; Gavin A McKenzie
Journal:  Neuroradiol J       Date:  2021-03-08
  4 in total