Automated liver sampling using a gradient dual-echo Dixon-based technique.

Mustafa R Bashir1, Brian M Dale, Elmar M Merkle, Daniel T Boll.   

Abstract

Magnetic resonance spectroscopy of the liver requires input from a physicist or physician at the time of acquisition to insure proper voxel selection, while in multiecho chemical shift imaging, numerous regions of interest must be manually selected in order to ensure analysis of a representative portion of the liver parenchyma. A fully automated technique could improve workflow by selecting representative portions of the liver prior to human analysis. Complete volumes from three-dimensional gradient dual-echo acquisitions with two-point Dixon reconstruction acquired at 1.5 and 3 T were analyzed in 100 subjects, using an automated liver sampling algorithm, based on ratio pairs calculated from signal intensity image data as fat-only/water-only and log(in-phase/opposed-phase) on a voxel-by-voxel basis. Using different gridding variations of the algorithm, the average correct liver volume samples ranged from 527 to 733 mL. The average percentage of sample located within the liver ranged from 95.4 to 97.1%, whereas the average incorrect volume selected was 16.5-35.4 mL (2.9-4.6%). Average run time was 19.7-79.0 s. The algorithm consistently selected large samples of the hepatic parenchyma with small amounts of erroneous extrahepatic sampling, and run times were feasible for execution on an MRI system console during exam acquisition.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22190284     DOI: 10.1002/mrm.23123

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Automated two-point dixon screening for the evaluation of hepatic steatosis and siderosis: comparison with R2-relaxometry and chemical shift-based sequences.

Authors:  B Henninger; H Zoller; S Rauch; M Schocke; S Kannengiesser; X Zhong; G Reiter; W Jaschke; C Kremser
Journal:  Eur Radiol       Date:  2014-12-14       Impact factor: 5.315

2.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

3.  Detection of Liver Steatosis With a Novel Ultrasound-Based Technique: A Pilot Study Using MRI-Derived Proton Density Fat Fraction as the Gold Standard.

Authors:  Giovanna Ferraioli; Laura Maiocchi; Maria Vittoria Raciti; Carmine Tinelli; Annalisa De Silvestri; Mara Nichetti; Pasquale De Cata; Mariangela Rondanelli; Luca Chiovato; Fabrizio Calliada; Carlo Filice
Journal:  Clin Transl Gastroenterol       Date:  2019-10       Impact factor: 4.488

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.