Literature DB >> 22190271

[Soft tissue reconstruction of the distal lower extremity using the 180-degree perforator-based propeller flap].

R G Jakubietz1, K Schmidt, B M Holzapfel, R H Meffert, M Rudert, M G Jakubietz.   

Abstract

OBJECTIVE: Operative technique of propeller flap reconstruction of soft tissue defects in the distal lower extremity. Soft tissue reconstruction of the distal third of the lower extremity with local, reliable perforator flaps avoiding free tissue transfer. INDICATIONS: Complex wounds (maximum width of 6 cm) of the distal lower extremity with exposed bones, joints, tendons, and neurovascular structures. CONTRAINDICATIONS: Arterial vascular disease (stage III or IV), diabetes mellitus, postthrombotic syndrome, venous ulcers, chronic lymphedema, contusion of adjacent soft tissue, previous radiation, and lack of perforators SURGICAL TECHNIQUE: The perforator represents the pivot point around which rotation of up to 180º of the subfascially harvested flap allows closure of the defect. The proximal donor site can be closed primarily up to a width of 6 cm. POSTOPERATIVE MANAGEMENT: Strict elevation of the extremity for 5 days, then flap conditioning.
RESULTS: This technique was used for soft tissue reconstruction in 17 patients. In one patient with diabetes, complete flap necrosis occurred, requiring amputation of the extremity. One case of epidermolysis healed without further surgery.

Entities:  

Mesh:

Year:  2012        PMID: 22190271     DOI: 10.1007/s00064-011-0090-2

Source DB:  PubMed          Journal:  Oper Orthop Traumatol        ISSN: 0934-6694            Impact factor:   1.154


  9 in total

Review 1.  The propeller flap concept.

Authors:  Tiew Chong Teo
Journal:  Clin Plast Surg       Date:  2010-10       Impact factor: 2.017

2.  The propeller flap method.

Authors:  H Hyakusoku; T Yamamoto; M Fumiiri
Journal:  Br J Plast Surg       Date:  1991-01

3.  The vascular territories (angiosomes) of the body: experimental study and clinical applications.

Authors:  G I Taylor; J H Palmer
Journal:  Br J Plast Surg       Date:  1987-03

4.  [Propeller flaps: the reliability of preoperative, unidirectional Doppler sonography].

Authors:  R G Jakubietz; M G Jakubietz; J G Grünert; R K Zahn; R H Meffert; K Schmidt
Journal:  Handchir Mikrochir Plast Chir       Date:  2011-04-20       Impact factor: 1.018

5.  Lower limb reconstruction using the islanded posterior tibial artery perforator flap.

Authors:  Mark V Schaverien; Stuart A Hamilton; Neil Fairburn; Pradeep Rao; Awf A Quaba
Journal:  Plast Reconstr Surg       Date:  2010-06       Impact factor: 4.730

6.  The versatility of propeller flaps for lower limb reconstruction in patients with peripheral arterial obstructive disease: initial experience.

Authors:  Lucian P Jiga; Sorin Barac; Georgel Taranu; Alexandru Blidisel; Vlad Dornean; Alexandru Nistor; Teodora Stoichitoiu; Max Geishauser; Mihai Ionac
Journal:  Ann Plast Surg       Date:  2010-02       Impact factor: 1.539

7.  Free-style free flaps.

Authors:  Fu-Chan Wei; Samir Mardini
Journal:  Plast Reconstr Surg       Date:  2004-09-15       Impact factor: 4.730

8.  The influence of pedicle length on the viability of twisted perforator flaps in rats.

Authors:  Cheol-Ho Chang; So-Young Lim; Jai-Kyong Pyon; Sa-Ik Bang; Kap-Sung Oh; Goo-Hyun Mun
Journal:  J Reconstr Microsurg       Date:  2009-08-12       Impact factor: 2.873

9.  The 180-degree perforator-based propeller flap for soft tissue coverage of the distal, lower extremity: a new method to achieve reliable coverage of the distal lower extremity with a local, fasciocutaneous perforator flap.

Authors:  Rafael G Jakubietz; Michael G Jakubietz; Joerg G Gruenert; Danni F Kloss
Journal:  Ann Plast Surg       Date:  2007-12       Impact factor: 1.539

  9 in total
  1 in total

Review 1.  [Local flaps as a last attempt to avoid lower extremity amputation: an overview].

Authors:  Rafael G Jakubietz; Rainer H Meffert; Michael G Jakubietz; Florian Seyfried; Karsten Schmidt
Journal:  Unfallchirurg       Date:  2020-12       Impact factor: 1.000

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.