Comparative study of periapical radiographic techniques with apex locator for endodontic working length estimation: an ex vivo study.

Vaishali Parekh1, Chirag Taluja.   

Abstract

BACKGROUND: Accurate assessment of working length determines the success and prognosis of an endodontic treatment outcome. Various methods are used in determining the working length. AIM: Compare the measurements of the apex locator and radiographic technique to determine working length.
METHODS: An ex vivo study was conducted on 20 patients having intact single straight root canal. Only premolars were taken in the study. After doing coronal flaring and irrigation, the radiographic length was determined with an aid of a k-type file and electronic length (EL-Root-ZX) 3rd generation apex locator. After extraction of all the premolars, stereomicroscope was further used to confirm and compare radiographic and electronic apex locator.
RESULTS: A mean value of 0.5430 ± 0.5741 mm was observed among radiographic techniques. A mean value of 0.4240 ± 0.4587 mm was observed among apex locator techniques. T-test revealed, no significant difference between the two techniques was observed (p = 0. 615). 'Two tailed' t-test revealed intragroup significance both techniques for determining the working length.
CONCLUSION: The distance of the apical foramen to the tip of the file: A mean value of 0.4240 ± 0.4587 mm with apex locator technique was observed. Working length of apex locator was more in comparison to radiographic technique. No significant difference between the two techniques was observed (p = 0. 615). Intragroup significance among both techniques for determining the working length was also observed. However, a further study incorporating a larger sample size and utilization of both techniques of working length determination on the same tooth has to be conducted. CLINICAL SIGNIFICANCE: Combining the apex locator technique and radiographic technique for determination of working length would yield more accurate working length.

Entities:  

Mesh:

Year:  2011        PMID: 22186757     DOI: 10.5005/jp-journals-10024-1022

Source DB:  PubMed          Journal:  J Contemp Dent Pract        ISSN: 1526-3711


  2 in total

1.  Comparison of Accuracy of Apex Locator with Tactile and Conventional Radiographic Method for Working Length Determination in Primary and Permanent Teeth.

Authors:  Khushboo Rathore; Sandeep Tandon; Meenakshi Sharma; Garima Kalia; Tejshree Shekhawat; Yogendra Chundawat
Journal:  Int J Clin Pediatr Dent       Date:  2020 May-Jun

Review 2.  A systematic review of nonsurgical single-visit versus multiple-visit endodontic treatment.

Authors:  Amy Wy Wong; Chengfei Zhang; Chun-Hung Chu
Journal:  Clin Cosmet Investig Dent       Date:  2014-05-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.