Literature DB >> 22186447

Automated coring and apical connector insertion device for aortic valve bypass surgery.

Corey Adams1, Linrui Ray Guo, Philip M Jones, Christopher Harle, John W Brown, James S Gammie, Bob Kiaii.   

Abstract

PURPOSE: The technical difficulty of performing the left ventricular apical anastomosis has limited the adoption of aortic valve bypass surgery for the treatment of aortic stenosis. We report the successful use of an automated coring and apical connector device to perform aortic valve bypass surgery. DESCRIPTION: A 74-year-old man, with a history of prior coronary bypass surgery with patent grafts and a porcelain ascending aorta, presented with symptomatic critical aortic stenosis. Through a left anterolateral thoracotomy, a valved conduit was anastomosed to the descending thoracic aorta. The automated coring and apical connector insertion device was used to core a plug of apical myocardium and simultaneously insert an 18-mm apical connector into the left ventricular apex. EVALUATION: There were no procedural complications, cardiopulmonary bypass was not used, and estimated blood loss was minimal. The patient was discharged on postoperative day 5, and at 3-month follow-up demonstrated significant clinical and hemodynamic improvement.
CONCLUSIONS: The automated coring and apical connector insertion device facilitated the safe and effective performance of aortic valve bypass surgery.
Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22186447     DOI: 10.1016/j.athoracsur.2011.08.063

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  eComment. Aortic valve conduit should not be performed in the presence of severe aortic regurgitation.

Authors:  Jamil Hajj-Chahine
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-12

2.  Aortic valve bypass: experience from Denmark.

Authors:  Jens T Lund; Maiken B Jensen; Henrik Arendrup; Nikolaj Ihlemann
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-03-25

3.  Apicoaortic conduit and cerebral perfusion in mixed aortic valve disease: a computational analysis.

Authors:  Gionata Fragomeni; Michele Rossi; Francesca Condemi; Rosario Mazzitelli; Giuseppe Filiberto Serraino; Attilio Renzulli
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-08-20

4.  Early experiences and in-hospital results with a novel off-pump apico-aortic conduit.

Authors:  Oliver Reuthebuch; Jens Fassl; John Brown; Martin Grapow; Friedrich Eckstein
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-01-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.