Literature DB >> 22185484

Screening and selective quantification of illicit drugs in wastewater by mixed-mode solid-phase extraction and quadrupole-time-of-flight liquid chromatography-mass spectrometry.

Iria González-Mariño1, José Benito Quintana, Isaac Rodríguez, Marta González-Díez, Rafael Cela.   

Abstract

For the first time, a mixed-mode solid-phase extraction with fractionation of basic analytes from neutral and acidic species during cartridge elution and liquid chromatography-quadrupole-time-of-flight mass spectrometry (LC-QTOF-MS) was combined for the quantitative determination of 24 illicit drugs and metabolites in urban sewage samples. The effects of several sample preparation and instrumental parameters in the sensitivity and selectivity of the quantitative method are thoroughly discussed. Under final working conditions, recoveries above 63% and 82% were attained for all species in raw and treated sewage, respectively; whereas, the limits of quantification of the method, defined for a signal-to-noise of 10 (S/N = 10), ranged from 2 to 50 ng L(-1). Sequential elution of mixed-mode cartridges allowed a significant reduction of matrix effects observed during electrospray ionization of basic drugs versus those measured for hydrophilic balance reversed-phase sorbents and the same mixed-mode polymer without fractionated elution. Analysis of raw wastewater samples confirmed the ubiquity of cocaine (COC), benzoylecgonine (BE), and 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THCCOOH) in this matrix. The capability of the above methodology to identify new illicit drugs and/or metabolites in sewage samples is also discussed. With this aim, a two step strategy is proposed. First, high-resolution MS chromatograms, acquired throughout each chromatographic run, are automatically searched against an in-house built database, a reduced list of candidate drugs is generated, and the corresponding extracted ion chromatograms are obtained. In a further LC run, the tandem mass spectrometry (MS/MS) spectra of unknown peaks are acquired using different collision energies and compared with those existing in public libraries, or interpreted, to assign the unknown peak to one of the previously selected candidates.
© 2011 American Chemical Society

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22185484     DOI: 10.1021/ac202989e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Detection of veterinary drug residues in surface waters collected nearby farming areas in Galicia, North of Spain.

Authors:  Alejandra Iglesias; Carolina Nebot; Beatriz I Vázquez; Jose M Miranda; Carlos M Franco Abuín; Alberto Cepeda
Journal:  Environ Sci Pollut Res Int       Date:  2013-09-26       Impact factor: 4.223

2.  A Simple, Rapid and Reliable Method to Determine Imipramine and Desipramine in Mouse Serum Using Ultra-High-Performance Liquid Chromatography-Quadrupole-Time-of-Flight Mass Spectrometry.

Authors:  Jing Zhao; Yujin Shin; Kwang-Hoon Chun; Hye-Ran Yoon; Jeongmi Lee
Journal:  J Chromatogr Sci       Date:  2015-12-19       Impact factor: 1.618

3.  Identification and profiling of targeted oxidized linoleic acid metabolites in rat plasma by quadrupole time-of-flight mass spectrometry.

Authors:  Zhi-Xin Yuan; Stanley I Rapoport; Steven J Soldin; Alan T Remaley; Ameer Y Taha; Matthew Kellom; Jianghong Gu; Maureen Sampson; Christopher E Ramsden
Journal:  Biomed Chromatogr       Date:  2012-10-05       Impact factor: 1.902

4.  Use of Sugar Cane Bagasse as Solid Extraction Phase Sorbent to Analyze Hormones from Industrial Effluent.

Authors:  Daniel T Lebre; Velaphi C Thipe; Marycel E B Cotrim; José Oscar V Bustillos
Journal:  ACS Omega       Date:  2022-03-14

5.  Solid-phase extraction and fractionation of multiclass pollutants from wastewater followed by liquid chromatography tandem-mass spectrometry analysis.

Authors:  V Fernández-Fernández; M Ramil; R Cela; I Rodríguez
Journal:  Anal Bioanal Chem       Date:  2022-04-23       Impact factor: 4.478

6.  High-Throughput Effect-Directed Analysis Using Downscaled in Vitro Reporter Gene Assays To Identify Endocrine Disruptors in Surface Water.

Authors:  Nick Zwart; Shan Li Nio; Corine J Houtman; Jacob de Boer; Jeroen Kool; Timo Hamers; Marja H Lamoree
Journal:  Environ Sci Technol       Date:  2018-03-26       Impact factor: 9.028

Review 7.  Mass spectrometric strategies for the investigation of biomarkers of illicit drug use in wastewater.

Authors:  Félix Hernández; Sara Castiglioni; Adrian Covaci; Pim de Voogt; Erik Emke; Barbara Kasprzyk-Hordern; Christoph Ort; Malcolm Reid; Juan V Sancho; Kevin V Thomas; Alexander L N van Nuijs; Ettore Zuccato; Lubertus Bijlsma
Journal:  Mass Spectrom Rev       Date:  2016-10-17       Impact factor: 10.946

8.  Quantitative analysis of opioids and cannabinoids in wastewater samples.

Authors:  Alethea Jacox; Jillian Wetzel; Shu-Yuan Cheng; Marta Concheiro
Journal:  Forensic Sci Res       Date:  2017-01-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.