Literature DB >> 22184167

Non-vascularised fibular graft as an intramedullary strut for infected non-union of the humerus.

G Gopisankar1, Arockiaraj S V Justin, Manasseh Nithyananth, Vinoo M Cherian, V N Lee.   

Abstract

PURPOSE. To review outcomes of 7 patients who underwent revision surgery for infected non-union of the humerus using a fibular graft as an intramedullary strut. METHODS. Records of 7 men aged 29 to 59 (mean, 40) years with humeral diaphyseal infected non-union who underwent fixation using a compression plate and a non-vascularised fibular graft as an intramedullary strut were reviewed. The mean number of previous surgeries was 2.7 (range, 2-4). Three of the patients had active draining sinuses previously. Their C-reactive protein levels were normal and tissue cultures negative. The remaining 4 patients had active draining sinuses. They first underwent implant removal and debridement. Tissue cultures confirmed infection in 3 of them. The mean duration between debridement and the index surgery was 5 (range, 3-10) months. RESULTS. The mean length of the fibulae harvested was 13 (range, 12-15) cm. All 7 non-unions healed. The mean time to healing was 5.4 (range, 4-8) months. The mean follow-up period was 15 (range, 13-24) months. All patients had weakness of the extensor hallucis longus, which improved to near normal at month 3. There was no donor-site morbidity. Three patients with active infection at presentation underwent repeat surgery. Two of them had wound washouts, and their non-unions went on to heal successfully; one underwent implant removal after union due to an active sinus. Six of the patients returned to their pre-injury activity level, and one endured a brachial plexus injury. CONCLUSION. Fixation using a compression plate and a non-vascularised fibular graft as an intramedullary strut achieved good outcome for infected non-union of the humerus despite prior multiple failed surgeries.

Entities:  

Mesh:

Year:  2011        PMID: 22184167     DOI: 10.1177/230949901101900316

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  4 in total

1.  [Treatment of tibial pseudoarthrosis. Complications after intramedullary, allogeneic fibular grafting].

Authors:  T Helfen; W C Prall; W Mutschler; P H Thaller
Journal:  Unfallchirurg       Date:  2015-04       Impact factor: 1.000

2.  Autologous Nonvascularized Fibula Graft and Locking Compression Plating for Failed Fixation of Humeral Shaft With Atrophic Gap Nonunion.

Authors:  Karan Shetty; Naga Cheppalli; Deepak Kaki
Journal:  Cureus       Date:  2022-04-19

3.  Role of autologous non-vascularised intramedullary fibular strut graft in humeral shaft nonunions following failed plating.

Authors:  Sreekanth Kashayi-Chowdojirao; Aashish Vallurupalli; Vijay Krishna Chilakamarri; Chandrasekhar Patnala; Lalith Mohan Chodavarapu; Nageswara Rao Kancherla; Asif Hussain Khazi Syed
Journal:  J Clin Orthop Trauma       Date:  2016-12-22

4.  Salvage of a recalcitrant humeral shaft septic nonunion using a linked nail-plate fixation construct with intercalary allograft.

Authors:  Sandip P Tarpada; Abraham M Goch; Jeremy Loloi; Milan K Sen
Journal:  Trauma Case Rep       Date:  2021-02-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.