PURPOSE: To evaluate the results of single-suture scleral fixation of subluxated foldable intraocular lenses (IOL) in eyes with sufficient residual capsular support.
METHODS: The results of IOL repositioning by single-suture scleral fixation in 6 eyes of 6 patients with IOL subluxation were included. All subluxated IOLs were single-piece hydrophilic acrylic. Subluxation resulted from posterior capsule tears in 3 eyes, zonular dialyses in 2 eyes, and zonular dialysis with a capsulorhexis tear in 1 eye. A similar technique was used in all eyes in which one haptic was externalized through a superior clear corneal incision and tied with a Pair-PAK 10-0 polypropylene suture, and was finally retracted and fixated behind the iris close to the ciliary sulcus at the 12:00 meridian. All patients were followed up for at least 6 months.
RESULTS: Best-corrected visual acuities ranged between finger counting and 20/70 (mean logMAR 1.02±0.64) preoperatively, and between 20/100 and 20/20 (mean logMAR 0.22±0.26) at the final postoperative visit. All IOLs remained centered and no significant postoperative complications were encountered except for an IOL tilt which resulted in a considerable oblique astigmatism in one eye.
CONCLUSIONS: Subluxated foldable IOLs may safely be repositioned and secured with a single scleral fixation suture in selected cases with adequate amount of capsular remnants.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22180152     DOI: 10.5301/ejo.5000094

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  3 in total

1.  A case of decentered IOL managed with optic buttonholing.

Authors:  Shikha Gupta; Sudarshan Khokhar; Tushar Agarwal
Journal:  Int Ophthalmol       Date:  2014-09-17       Impact factor: 2.031

2.  Simplified ab externo fixation technique to treat late dislocation of scleral-sutured polymethyl methacrylate intraocular lenses.

Authors:  J Lyu; P-Q Zhao
Journal:  Eye (Lond)       Date:  2016-01-22       Impact factor: 3.775

3.  Malik`s Technique of Single Loop Fixation of Posterior Chamber Intraocular Lens in Presence of Partial Capsular Support.

Authors:  Krishan Pal Singh Malik; Ruchi Goel; Divya Kishore; Smriti Nagpal
Journal:  Open Ophthalmol J       Date:  2015-12-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.