Literature DB >> 22180063

Axillary recurrence rate 5 years after negative sentinel node biopsy for breast cancer.

Y Andersson1, J de Boniface, P-E Jönsson, C Ingvar, G Liljegren, L Bergkvist, J Frisell.   

Abstract

BACKGROUND: Sentinel lymph node (SLN) biopsy has replaced axillary lymph node dissection (ALND) as the standard axillary staging procedure in breast cancer. Follow-up studies in SLN-negative women treated without ALND report low rates of axillary recurrence, but most studies have short follow-up, and few are multicentre studies.
METHODS: Between September 2000 and January 2004, patients who were SLN-negative and did not have ALND were included in a prospective cohort. Kaplan-Meier estimates were used to analyse the rates of axillary recurrence and survival. The risk of axillary recurrence was also compared in centres with high and low experience with the SLN biopsy (SLNB) technique.
RESULTS: A total of 2195 patients with 2216 breast tumours were followed for a median of 65 months. Isolated axillary recurrence was diagnosed in 1·0 per cent of patients. The event-free 5-year survival rate was 88·8 per cent and the overall 5-year survival rate 93·1 per cent. There was no difference in recurrence rates between centres contributing fewer than 150 SLNB procedures to the cohort and centres contributing 150 or more procedures.
CONCLUSION: This study confirmed the low risk of axillary recurrence 5 years after SLNB for breast cancer without ALND.
Copyright © 2011 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 22180063     DOI: 10.1002/bjs.7820

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  10 in total

1.  Regional Disease Control in Selected Patients with Sentinel Lymph Node Involvement and Omission of Axillary Lymph Node Dissection.

Authors:  Gábor Cserni; Róbert Maráz
Journal:  Pathol Oncol Res       Date:  2015-02-04       Impact factor: 3.201

2.  Oestrogen receptors β1 and βcx have divergent roles in breast cancer survival and lymph node metastasis.

Authors:  G Rosin; J de Boniface; G M Karthik; J Frisell; J Bergh; J Hartman
Journal:  Br J Cancer       Date:  2014-07-15       Impact factor: 7.640

3.  A mini-review on factors and countermeasures associated with false-negative sentinel lymph node biopsies in breast cancer.

Authors:  Chao Han; Li Yang; Wenshu Zuo
Journal:  Chin J Cancer Res       Date:  2016-06       Impact factor: 5.087

4.  Survival and axillary recurrence following sentinel node-positive breast cancer without completion axillary lymph node dissection: the randomized controlled SENOMAC trial.

Authors:  Jana de Boniface; Jan Frisell; Yvette Andersson; Leif Bergkvist; Johan Ahlgren; Lisa Rydén; Roger Olofsson Bagge; Malin Sund; Hemming Johansson; Dan Lundstedt
Journal:  BMC Cancer       Date:  2017-05-26       Impact factor: 4.430

5.  Swedish prospective multicenter trial on the accuracy and clinical relevance of sentinel lymph node biopsy before neoadjuvant systemic therapy in breast cancer.

Authors:  Linda Zetterlund; Fuat Celebioglu; Rimma Axelsson; Jana de Boniface; Jan Frisell
Journal:  Breast Cancer Res Treat       Date:  2017-02-17       Impact factor: 4.872

6.  Role of number of sentinel nodes in predicting non-sentinel node metastasis in breast cancer.

Authors:  Li-Feng Dong; Shu-Ying Xu; Jing-Pei Long; Fang Wan; Yi-Ding Chen
Journal:  J Int Med Res       Date:  2017-09-18       Impact factor: 1.671

7.  Breast-conserving surgery followed by whole-breast irradiation offers survival benefits over mastectomy without irradiation.

Authors:  J de Boniface; J Frisell; L Bergkvist; Y Andersson
Journal:  Br J Surg       Date:  2018-06-21       Impact factor: 6.939

8.  Do clinical trials truly mirror their target population? An external validity analysis of national register versus trial data from the Swedish prospective SENOMIC trial on sentinel node micrometastases in breast cancer.

Authors:  Y Andersson; L Bergkvist; J Frisell; J de Boniface
Journal:  Breast Cancer Res Treat       Date:  2019-06-24       Impact factor: 4.872

9.  Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer.

Authors:  Chao Han; Ben Yang; Wen-Shu Zuo; Yan-Song Liu; Gang Zheng; Li Yang; Mei-Zhu Zheng
Journal:  Chin J Cancer       Date:  2016-04-04

10.  Factors that affect the false negative rate of sentinel lymph node mapping with methylene blue dye alone in breast cancer.

Authors:  Huang Li; Zhang Jun; Ge Zhi-Cheng; Qu Xiang
Journal:  J Int Med Res       Date:  2019-09-11       Impact factor: 1.671

  10 in total