Measurement of impulse peak insertion loss for four hearing protection devices in field conditions.

William J Murphy1, Gregory A Flamme, Deanna K Meinke, Jacob Sondergaard, Donald S Finan, James E Lankford, Amir Khan, Julia Vernon, Michael Stewart.   

Abstract

OBJECTIVE: In 2009, the U.S. Environmental Protection Agency (EPA) proposed an impulse noise reduction rating (NRR) for hearing protection devices based upon the impulse peak insertion loss (IPIL) methods in the ANSI S12.42-2010 standard. This study tests the ANSI S12.42 methods with a range of hearing protection devices measured in field conditions.
DESIGN: The method utilizes an acoustic test fixture and three ranges for impulse levels: 130-134, 148-152, and 166-170 dB peak SPL. For this study, four different models of hearing protectors were tested: Bilsom 707 Impact II electronic earmuff, E·A·R Pod Express, E·A·R Combat Arms version 4, and the Etymotic Research, Inc. Electronic BlastPLG™ EB1. STUDY SAMPLE: Five samples of each protector were fitted on the fixture or inserted in the fixture's ear canal five times for each impulse level. Impulses were generated by a 0.223 caliber rifle.
RESULTS: The average IPILs increased with peak pressure and ranged between 20 and 38 dB. For some protectors, significant differences were observed across protector examples of the same model, and across insertions.
CONCLUSIONS: The EPA's proposed methods provide consistent and reproducible results. The proposed impulse NRR rating should utilize the minimum and maximum protection percentiles as determined by the ANSI S12.42-2010 methods.

Entities:  

Mesh:

Year:  2011        PMID: 22176308      PMCID: PMC4677999          DOI: 10.3109/14992027.2011.630330

Source DB:  PubMed          Journal:  Int J Audiol        ISSN: 1499-2027            Impact factor:   2.117


  19 in total

1.  Four earplugs in search of a rating system.

Authors:  J R Franks; W J Murphy; J L Johnson; D A Harris
Journal:  Ear Hear       Date:  2000-06       Impact factor: 3.570

2.  Hearing protector attenuation: models of attenuation distributions.

Authors:  William J Murphy; John R Franks; Edward F Krieg
Journal:  J Acoust Soc Am       Date:  2002-05       Impact factor: 1.840

3.  Development of a new standard laboratory protocol for estimation of the field attenuation of hearing protection devices: sample size necessary to provide acceptable reproducibility.

Authors:  William J Murphy; John R Franks; Elliott H Berger; Alberto Behar; John G Casali; Christine Dixon-Ernst; Edward F Krieg; Ben T Mozo; Julia D Royster; Larry H Royster; Stephen D Simon; Carol Stephenson
Journal:  J Acoust Soc Am       Date:  2004-01       Impact factor: 1.840

4.  Application of the kurtosis statistic to the evaluation of the risk of hearing loss in workers exposed to high-level complex noise.

Authors:  Yi-Ming Zhao; Wei Qiu; Lin Zeng; Shan-Song Chen; Xiao-Ru Cheng; Robert I Davis; Roger P Hamernik
Journal:  Ear Hear       Date:  2010-08       Impact factor: 3.570

5.  Attenuation of high-level impulses by earmuffs.

Authors:  Jan Zera; Rafal Mlynski
Journal:  J Acoust Soc Am       Date:  2007-10       Impact factor: 1.840

6.  Assessment of noise exposure for indoor and outdoor firing ranges.

Authors:  William J Murphy; Randy L Tubbs
Journal:  J Occup Environ Hyg       Date:  2007-09       Impact factor: 2.155

7.  Estimates of auditory risk from outdoor impulse noise. II: Civilian firearms.

Authors:  Gregory A Flamme; Adam Wong; Kevin Liebe; James Lynd
Journal:  Noise Health       Date:  2009 Oct-Dec       Impact factor: 0.867

8.  Auditory risk to unprotected bystanders exposed to firearm noise.

Authors:  Gregory A Flamme; Michael Stewart; Deanna Meinke; James Lankford; Per Rasmussen
Journal:  J Am Acad Audiol       Date:  2011-02       Impact factor: 1.664

9.  Noise levels and hearing thresholds in the drop forging industry.

Authors:  W Taylor; B Lempert; P Pelmear; I Hemstock; J Kershaw
Journal:  J Acoust Soc Am       Date:  1984-09       Impact factor: 1.840

10.  Auditory and vestibular dysfunction associated with blast-related traumatic brain injury.

Authors:  Stephen A Fausti; Debra J Wilmington; Frederick J Gallun; Paula J Myers; James A Henry
Journal:  J Rehabil Res Dev       Date:  2009
View more
  8 in total

1.  Impulse noise generated by starter pistols.

Authors:  Deanna K Meinke; Donald S Finan; Jacob Soendergaard; Gregory A Flamme; William J Murphy; James E Lankford; Michael Stewart
Journal:  Int J Audiol       Date:  2013-02       Impact factor: 2.117

Review 2.  Prevention of Noise-Induced Hearing Loss from Recreational Firearms.

Authors:  Deanna K Meinke; Donald S Finan; Gregory A Flamme; William J Murphy; Michael Stewart; James E Lankford; Stephen Tasko
Journal:  Semin Hear       Date:  2017-10-10

3.  Spectral analysis of hearing protector impulsive insertion loss.

Authors:  Cameron J Fackler; Elliott H Berger; William J Murphy; Michael E Stergar
Journal:  Int J Audiol       Date:  2016-11-25       Impact factor: 2.117

4.  Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube.

Authors:  William J Murphy; Cameron J Fackler; Elliott H Berger; Peter B Shaw; Mike Stergar
Journal:  Noise Health       Date:  2015 Sep-Oct       Impact factor: 0.867

5.  Hearing loss associated with US military combat deployment.

Authors:  Timothy S Wells; Amber D Seelig; Margaret A K Ryan; Jason M Jones; Tomoko I Hooper; Isabel G Jacobson; Edward J Boyko
Journal:  Noise Health       Date:  2015 Jan-Feb       Impact factor: 0.867

6.  Selection of Level-Dependent Hearing Protectors for Use in An Indoor Shooting Range.

Authors:  Rafal Mlynski; Emil Kozlowski
Journal:  Int J Environ Res Public Health       Date:  2019-06-27       Impact factor: 3.390

7.  Localization of Vehicle Back-Up Alarms by Users of Level-Dependent Hearing Protectors under Industrial Noise Conditions Generated at a Forge.

Authors:  Rafal Mlynski; Emil Kozlowski
Journal:  Int J Environ Res Public Health       Date:  2019-01-30       Impact factor: 3.390

8.  Evaluation of hearing protection used by police officers in the shooting range.

Authors:  Heraldo Lorena Guida; Carla Linhares Taxini; Claudia Giglio de Oliveira Gonçalves; Vitor Engrácia Valenti
Journal:  Braz J Otorhinolaryngol       Date:  2014-08-22
  8 in total