Laryngeal mask airway classic as a rescue device after accidental extubation in a neonate in prone position.

Susheela Taxak1, Ajith Gopinath.   

Abstract

Entities:  

Year:  2011        PMID: 22174479      PMCID: PMC3237162          DOI: 10.4103/0019-5049.89902

Source DB:  PubMed          Journal:  Indian J Anaesth        ISSN: 0019-5049


× No keyword cloud information.
Sir, We report a case of accidental extubation in a neonate who underwent surgery in prone position, and subsequent airway management with an Laryngeal mask airway (LMA) classic, in the same position. A 6-day-old male child, weighing 2.65 kg was posted for surgical repair of meningomyelocele. After induction of anaesthesia, and adequate muscle relaxation, the trachea was intubated with an uncuffed tube of 3-mm internal diameter. The tube was connected to the paediatric circuit and positive pressure ventilation instituted. After checking for proper placement and adequate ventilation, the tracheal tube was secured with a fixation tape. The child was turned prone for the surgery, with the head turned towards his left side. About 20 minutes after the surgery had commenced, inadequate ventilation of lungs was noticed, as evidenced by the feel of the bag, and disappearance of the end-tidal CO2 graph. The tracheal tube had slipped out and the tip was found to be in the oral cavity, which probably occurred due to wetting of fixation tape by saliva, and subsequent tube displacement. The tube was removed, and a size 1 LMA Classic was inserted with the cuff partially deflated, in the first attempt. After inflating the cuff, the airway tube was connected to the breathing circuit and positive pressure ventilation reinstituted. The ventilation was adequate, as evidenced by equal bilateral air entry and the capnograph trace on the monitor. The O2 saturation was 100% during the sequence of events. The surgery was completed in another 15 minutes, during which the haemodynamic and respiratory parameters were normal. The child was turned supine, and neuromuscular blockade was reversed when he was conscious. The LMA was removed, following which, gentle oral suction was done. The postoperative period was uneventful. Another way of managing this complication would have been turning the child supine, and reintubating the trachea. But turning the patient supine and managing the patient would mean a little longer time without a definite airway and ventilation in an anaesthetized, paralyzed neonate. In addition, the risk of spinal cord injury and compromising the surgical field sterility in this case during such manipulation made us consider securing airway in the prone position. Moreover, we had a size 1 LMA Classic ready on the anaesthesia cart and the authors are experienced in the use of various supraglottic airway devices in the prone position in adult patients.[1] Several authors have reported management of accidental extubation in prone position with LMA Classic.[23] To the best of our knowledge, this is the first report of such an instance in a neonate.
  3 in total

1.  Insertion of the i-gel airway in prone position.

Authors:  S Taxak; A Gopinath
Journal:  Minerva Anestesiol       Date:  2010-05       Impact factor: 3.051

2.  Emergency airway management with a laryngeal mask airway in a patient placed in the prone position.

Authors:  Jacob Raphael; Tatyana Rosenthal-Ganon; Yaacov Gozal
Journal:  J Clin Anesth       Date:  2004-11       Impact factor: 9.452

3.  The use of a laryngeal mask airway for emergent airway management in a prone child.

Authors:  R Scott Dingeman; Liliana C Goumnerova; Susan M Goobie
Journal:  Anesth Analg       Date:  2005-03       Impact factor: 5.108

  3 in total
  5 in total

1.  Management of accidental extubation during oral surgery by nasotracheal intubation using the King vision video laryngoscope and a gum elastic bougie - a case report.

Authors:  Qazi Ehsan Ali; Syed Hussain Amir; Shadab Kamal; Sonali Bansal
Journal:  Rom J Anaesth Intensive Care       Date:  2015-10

2.  Supraglottic airway device versus a channeled or non-channeled blade-type videolaryngoscope for accidental extubation in the prone position: A randomized crossover manikin study.

Authors:  Hiroyuki Oshika; Yukihide Koyama; Masataka Taguri; Koichi Maruyama; Go Hirabayashi; Shoko Merrit Yamada; Masashi Kohno; Tomio Andoh
Journal:  Medicine (Baltimore)       Date:  2018-06       Impact factor: 1.889

3.  ProSeal laryngeal mask airway™ insertion in the prone position: Optimal utilization of operation theatre personnel and time?

Authors:  Bimla Sharma; Jayashree Sood; Raminder Sehgal; Chand Sahai; Anjali Gera
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-04

4.  A prospective study to evaluate and compare laryngeal mask airway ProSeal and i-gel airway in the prone position.

Authors:  Susheela Taxak; Ajith Gopinath; Savita Saini; Teena Bansal; Mangal Singh Ahlawat; Manju Bala
Journal:  Saudi J Anaesth       Date:  2015 Oct-Dec

5.  Comparison of three supraglottic airway devices for airway rescue in the prone position: A manikin-based study.

Authors:  Babita Gupta; Surender Gupta; Bijaya Hijam; Pallavi Shende; Vimi Rewari
Journal:  J Emerg Trauma Shock       Date:  2015 Oct-Dec