Using toxicity testing to evaluate electrochemical reactor operations.

Greg L Saylor1, Linxi Chen, Margaret J Kupferle.   

Abstract

In the present study, the Microtox® test was used to track the toxicity of electrochemical effluents to the marine bacteria Vibrio fischeri as a function of reaction time. When electrochemistry was used to degrade aqueous phenol using different reactor configurations, two reaction pathways were identified, chlorine substitution and oxidation, depending on whether the electrolyte contained chloride. For a boron-doped diamond (BDD) anode, electrochemistry using Na₂SO₄ electrolyte produced a significantly more toxic effluent than when using NaCl electrolyte with all other conditions remaining the same. This effect is attributed to the reaction pathway, specifically the production of benzoquinone. Benzoquinone was produced only during electrochemistry using Na₂SO₄ and is the most toxic potential intermediate, having nearly 800 times more toxicity than phenol. Although the use of NaCl produced a lower toxicity effluent than Na₂SO₄, caution should be observed because of the production of chlorinated phenols, which can be of special environmental concern. When comparing graphite rod and BDD plate anodes in terms of toxicity evolution when using Na₂SO₄, BDD was found to produce a lower toxicity effluent; this is a result of the increased oxidizing power of BDD, reducing the formation of benzoquinone. In this comparison, the type of anode material/electrode configuration did not seem to affect which intermediates were detected but did affect the quantity of and rate of production of intermediates.
Copyright © 2011 SETAC.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22170029     DOI: 10.1002/etc.1719

Source DB:  PubMed          Journal:  Environ Toxicol Chem        ISSN: 0730-7268            Impact factor:   3.742


  2 in total

1.  Functional categories of microbial toxicity resulting from three advanced oxidation process treatments during management and disposal of contaminated water.

Authors:  Rebecca B Phillips; Ryan R James; Matthew L Magnuson
Journal:  Chemosphere       Date:  2019-08-09       Impact factor: 7.086

2.  Electrolyte selection and microbial toxicity for electrochemical oxidative water treatment using a boron-doped diamond anode to support site specific contamination incident response.

Authors:  Rebecca B Phillips; Ryan R James; Matthew L Magnuson
Journal:  Chemosphere       Date:  2018-01-06       Impact factor: 7.086