Literature DB >> 22167583

Half-time SPECT acquisition with resolution recovery for Tc-MIBI SPECT imaging in the assessment of hyperparathyroidism.

Ronen Bar1, Kinga Przewloka, Rachel Karry, Alex Frenkel, Avishay Golz, Zohar Keidar.   

Abstract

PURPOSE: Reduced SPECT acquisition time protocols have been recently developed based on collimator-detector response compensation reconstruction. The present study aims to evaluate the potential use of a short-time technetium-99m methoxyisobutylisonitrile (Tc99m-MIBI) SPECT algorithm in the investigation of parathyroid adenoma (PTA). PROCEDURES: Ninety patients (59 women; age range, 21-76 years) with biochemical evidence of hyperparathyroidism were referred for Tc99m-MIBI scintigraphy for diagnosis and localization of PTA. Standard full-time and half-time SPECT studies starting at 45 min after injection were performed in random order in all patients. PTA detection rate and overall image quality parameters were evaluated and graded for each study and compared for the two SPECT protocols.
RESULTS: Focal (99m)Tc-sestamibi uptake consistent with PTA was reported in 60 out of 90 studies (67%). Congruent results between the full- and half-time SPECT acquisition were found in 73 patients (81%). Minor disagreement between the two SPECT protocols with respect to PTA detectability was found in 17 patients but with no statistically significant difference (p = 0.67). The correlation coefficient between the two SPECTs was r = 0.88 (p < 0.0001), and the Bland-Altman correlation analysis confirmed the interchangeability of the two protocols. Image quality was reported as either good or excellent for all studies, and no statistical significant difference in image quality scoring between protocols was found (p = 0.155).
CONCLUSION: Parathyroid MIBI SPECT can be performed using the collimator-detector response compensation reconstruction algorithm for only half of the scanning time without compromising significant diagnostic data.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22167583     DOI: 10.1007/s11307-011-0530-2

Source DB:  PubMed          Journal:  Mol Imaging Biol        ISSN: 1536-1632            Impact factor:   3.488


  11 in total

Review 1.  Radionuclide imaging of the parathyroid glands.

Authors:  Christopher J Palestro; Maria B Tomas; Gene G Tronco
Journal:  Semin Nucl Med       Date:  2005-10       Impact factor: 4.446

Review 2.  Proceedings of the NIH Consensus Development Conference on diagnosis and management of asymptomatic primary hyperparathyroidism. Bethesda, Maryland, October 29-31, 1990.

Authors: 
Journal:  J Bone Miner Res       Date:  1991-10       Impact factor: 6.741

3.  New reconstruction algorithm allows shortened acquisition time for myocardial perfusion SPECT.

Authors:  Ines Valenta; Valerie Treyer; Lars Husmann; Oliver Gaemperli; Michael J Schindler; Bernhard A Herzog; Patrick Veit-Heibach; Ronny R Buechel; René Nkoulou; Aju P Pazhenkottil; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-11-18       Impact factor: 9.236

4.  Role of 99mTc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery.

Authors:  Domenico Rubello; Arianna Massaro; Silvia Cittadin; Lucia Rampin; Adil Al-Nahhas; Giuseppe Boni; Giuliano Mariani; Maria Rosa Pelizzo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-06-28       Impact factor: 9.236

5.  140 consecutive cases of minimally invasive, radio-guided parathyroidectomy: lessons learned and long-term results.

Authors:  M Shabtai; M Ben-Haim; Y Muntz; I Vered; D Rosin; J Kuriansky; O Zmora; D Olchovski; A Ayalon; S T Zwas
Journal:  Surg Endosc       Date:  2003-03-07       Impact factor: 4.584

6.  Comparison of SPECT/CT, SPECT, and planar imaging with single- and dual-phase (99m)Tc-sestamibi parathyroid scintigraphy.

Authors:  William C Lavely; Sibyll Goetze; Kent P Friedman; Jeffrey P Leal; Zhe Zhang; Elizabeth Garret-Mayer; Alan P Dackiw; Ralph P Tufano; Martha A Zeiger; Harvey A Ziessman
Journal:  J Nucl Med       Date:  2007-06-15       Impact factor: 10.057

7.  Minimally invasive video-assisted thyroidectomy and parathyroidectomy with intraoperative recurrent laryngeal nerve monitoring.

Authors:  Emad Kandil; Shafik N Wassef; Haytham Alabbas; Paul L Freidlander
Journal:  Int J Otolaryngol       Date:  2010-02-08

8.  Half-time SPECT myocardial perfusion imaging with attenuation correction.

Authors:  Iftikhar Ali; Terrence D Ruddy; Abdulaziz Almgrahi; Frank G Anstett; R Glenn Wells
Journal:  J Nucl Med       Date:  2009-03-16       Impact factor: 10.057

9.  A multicenter evaluation of a new post-processing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correction.

Authors:  Carmelo V Venero; Gary V Heller; Timothy M Bateman; A Iain McGhie; Alan W Ahlberg; Deborah Katten; Staci A Courter; Robert J Golub; James A Case; S James Cullom
Journal:  J Nucl Cardiol       Date:  2009-07-07       Impact factor: 5.952

10.  Acquiring diagnostic DaTSCAN images in claustrophobic or difficult patients using a 180 degrees configuration.

Authors:  Alp Notghi; Joseph O'Brien; Elizabeth A Clarke; William H Thomson
Journal:  Nucl Med Commun       Date:  2010-03       Impact factor: 1.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.