Effect of implant abutment modification on the extrusion of excess cement at the crown-abutment margin for cement-retained implant restorations.

Chandur Wadhwani1, Alfonso Piñeyro, Timothy Hess, Hai Zhang, Kwok-Hung Chung.   

Abstract

PURPOSE: To compare the effect of implant abutment modification on the amount of cement extruded at the crown-abutment margin and to evaluate the vertical discrepancy after cementation.
MATERIALS AND METHODS: Access openings of titanium abutments were modified with an opening (open) and placement of two vent holes 3 mm from the occlusal edge and 180 degrees apart (internal vent). Access openings were filled with resin material (closed) and used as controls. Each abutment was secured to an implant analog. Eugenol-free zinc oxide cement (TempBond NE) was selected to cement the cast crowns (n = 9) onto test abutments. The amount of cement extruded out of the margin was calculated, and vertical seating discrepancies were determined with a linear transducer device before and after cementation. Differences among groups were analyzed statistically.
RESULTS: The mean amount of extruded cement ranged from 36% to 90% of the total cement placed within the crowns. The order, from least to greatest amount of excess cement extrusion at the margins, was internal vent, open, and closed; significant differences were observed between test groups. The net vertical discrepancies of tested specimens ranged from -7 μm to +6 μm (mean, 0 μm). No statistically significant differences in vertical discrepancy were found between the groups.
CONCLUSIONS: Venting the hollow abutment resulted in the least amount of cement extrusion when compared to closing off the screw access channel or leaving it open. Within the limitations of this study, it may be concluded that the use of two, 0.75-mm radius vent holes placed 3 mm apical to the occlusal area of the abutment and 180 degrees apart will limit the amount of cement extruded into the gingival sulcus of implant-retained crowns.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22167429

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  Influence of abutment design on retention of metal copings cemented to implants.

Authors:  Albano Porto da Cunha; Glauco Pereira Moysés; Ana Christina Claro Neves; Rafael Pino Vitti; Flávia Cardoso da Rosa Goulart; Laís Regiane da Siva-Concílio
Journal:  Acta Biomater Odontol Scand       Date:  2016-01-26

Review 2.  A Systematic Review of Cementation Techniques to Minimize Cement Excess in Cement-Retained Implant Restorations.

Authors:  Rodolfo Reda; Alessio Zanza; Andrea Cicconetti; Shilpa Bhandi; Renzo Guarnieri; Luca Testarelli; Dario Di Nardo
Journal:  Methods Protoc       Date:  2022-01-17

3.  Selection of 1-mm venting or 2.5-mm screw access holes on implant crowns based on cement extrusion and retention capacity.

Authors:  Huangjun Zhou; Sixian Ye; Min Liu; Hao Feng; Cai Wen
Journal:  BMC Oral Health       Date:  2022-04-02       Impact factor: 2.757

4.  A finite element analysis of novel vented dental abutment geometries for cement-retained crown restorations.

Authors:  Lucas C Rodriguez; Juliana N Saba; Clark A Meyer; Kwok-Hung Chung; Chandur Wadhwani; Danieli C Rodrigues
Journal:  Clin Exp Dent Res       Date:  2016-06-14
  4 in total