Can transthoracic Doppler echocardiography be used to detect coronary slow flow phenomenon?

Shao-Ping Nie1, Li-Li Geng, Xiao Wang, Xiao-Shan Zhang, Ya Yang, Bai-Qiu Liu, Jun Li, Yan Qiao, Xin-Min Liu, Tai-Yang Luo, Jian-Zeng Dong, Xiao-Hui Liu, Chang-Sheng Ma.   

Abstract

BACKGROUND: Coronary slow flow phenomenon (CSFP) is an important, angiographic clinical entity but is lacking non-invasive detecting techniques. This study aimed to elucidate the value of transthoracic Doppler echocardiography (TTDE) in the diagnosis and monitoring of coronary slow flow in left anterior descending (LAD) coronary artery.
METHODS: We consecutively enrolled 27 patients with CSFP in LAD detected by coronary arteriography from August 2009 to April 2010. Thirty-eight patients with angiographically normal coronary flow served as control. Corrected thrombolysis in myocardial infarction (TIMI) frame count (CTFC) was used to document coronary flow velocities. All subjects underwent TTDE within 24 hours after coronary angiography. LAD flow was detected and the coronary diastolic peak velocities (DPV) and diastolic mean velocities (DMV) were calculated.
RESULTS: Sixty of 65 (92.3%) subjects successfully underwent TTDE. Baseline clinical characteristics were similar between the two groups. Coronary DPV and DMV of LAD were significantly lower in the CSFP group than in the control group ((0.228 ± 0.029) m/s vs. (0.302 ± 0.065) m/s, P = 0.000; (0.176 ± 0.028) m/s vs. (0.226 ± 0.052) m/s, P = 0.000, respectively). There was a high inverse correlation between CTFC and coronary DPV and DMV (r = -0.727, P = 0.000; r = -0.671, P = 0.000, respectively). Receiver operating characteristic (ROC) curve showed that the area under the curve (AUC) was less than one half for coronary DPV (AUC = 0.104) and DMV (AUC = 0.204), respectively.
CONCLUSIONS: In patients with CSFP, there is a high inverse correlation between CTFC and coronary diastolic flow velocities in the LAD coronary artery, as measured by TTDE. The value of TTDE in the monitoring and evaluation of coronary flow in patients with CSFP deserves further investigation.

Entities:  

Mesh:

Year:  2010        PMID: 22166625

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  2 in total

1.  Are biventricular systolic functions impaired in patient with coronoray slow flow? A prospective study with three dimensional speckle tracking.

Authors:  Tuğba Kemaloğlu Öz; Mehmet Eren; Işıl Atasoy; Tayfun Gürol; Özer Soylu; Bahadır Dağdeviren
Journal:  Int J Cardiovasc Imaging       Date:  2017-01-06       Impact factor: 2.357

2.  Assessment of left and right ventricular diastolic and systolic functions using two-dimensional speckle-tracking echocardiography in patients with coronary slow-flow phenomenon.

Authors:  Yonghuai Wang; Chunyan Ma; Yan Zhang; Zhengyu Guan; Shuang Liu; Yuling Li; Jun Yang
Journal:  PLoS One       Date:  2015-02-23       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.