Guidewire breakage: an unusual complication of anterior odontoid cannulated screw fixation.

Tamer Orief1, Sharaf Bin-Nafisah, Khaled Almusrea, Mohamed Alfawareh.   

Abstract

The preferred treatment of a type II odontoid fracture is anterior odontoid screw fixation to preserve the cervical spine range of movement. This case report describes an unusual complication of guidewire breakage during anterior odontoid cannulated screw fixation for a 52-year-old patient who presented with a type II odontoid fracture after a motor vehicle accident. The distal segment of the guidewire was bent over the tip of the cannulated odontoid screw and broke off during guidewire withdrawal. The three months follow-up computed tomography examination of the cervical spine showed acceptable screw placement, good odontoid process alignment with incomplete fusion, and no migration of the fractured segment of the guidewire. It is recommended that the guidewire be withdrawn once the cannulated screw is passed through the fractured site into the odontoid process and a new guidewire be used in each surgical procedure instead of been reused to avoid metal stress fatigue that can result in easy breakage.

Entities:  

Keywords:  Breakage; Complication; Fracture; Guidewire; Odontoid

Year:  2011        PMID: 22164322      PMCID: PMC3230655          DOI: 10.4184/asj.2011.5.4.258

Source DB:  PubMed          Journal:  Asian Spine J        ISSN: 1976-1902


  6 in total

1.  Tissue reaction to implants of different metals: a study using guide wires in cannulated screws.

Authors:  D M Devine; M Leitner; S M Perren; L P Boure; S G Pearce
Journal:  Eur Cell Mater       Date:  2009-10-20       Impact factor: 3.942

2.  Fractures of the odontoid process of the axis.

Authors:  L D Anderson; R T D'Alonzo
Journal:  J Bone Joint Surg Am       Date:  1974-12       Impact factor: 5.284

3.  Cannulated screws for odontoid screw fixation and atlantoaxial transarticular screw fixation. Technical note.

Authors:  C A Dickman; K T Foley; V K Sonntag; M M Smith
Journal:  J Neurosurg       Date:  1995-12       Impact factor: 5.115

4.  Anterior stabilization for acute fractures and non-unions of the dens.

Authors:  J Böhler
Journal:  J Bone Joint Surg Am       Date:  1982-01       Impact factor: 5.284

5.  Acute axis fractures: a review of 229 cases.

Authors:  M N Hadley; C A Dickman; C M Browner; V K Sonntag
Journal:  J Neurosurg       Date:  1989-11       Impact factor: 5.115

6.  Pathomechanisms of failures of the odontoid.

Authors:  C M Puttlitz; V K Goel; C R Clark; V C Traynelis
Journal:  Spine (Phila Pa 1976)       Date:  2000-11-15       Impact factor: 3.468

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.