Assessment of tophus size: a comparison between physical measurement methods and dual-energy computed tomography scanning.

Nicola Dalbeth1, Opetaia Aati, Angela Gao, Meaghan House, Qiliang Liu, Anne Horne, Anthony Doyle, Fiona M McQueen.   

Abstract

BACKGROUND: Dual-energy computed tomography (DECT) has recently been described as a sensitive method to detect urate deposits in patients with gout.
OBJECTIVES: The aim of this study was to compare the reproducibility of DECT with various physical measurement methods of tophus size assessment.
METHODS: Sixty-four tophi from 25 patients were analyzed. Each tophus was assessed by 2 independent observers using Vernier calipers and tape measure. All patients proceeded to DECT scanning of both feet. Urate volume within index tophi was assessed by 2 independent observers using automated DECT volume assessment software (n = 55 tophi). Five patients returned within 1 week for repeat physical assessment of tophus size. Dual-energy computed tomography scans from the returning patients were scored twice by both observers. Intraobserver and interobserver reproducibility was assessed by intraclass correlation coefficient (ICC) and limits-of-agreement analysis.
RESULTS: Overall, DECT was more reproducible than the physical methods with interobserver ICCs for DECT of 0.95, for calipers 0.78, and for tape measurement 0.88, and intraobserver ICCs for DECT of 1.00, for calipers 0.75, and for tape measurement 0.91. Vernier caliper and tape measurements correlated highly with each other (rs = 0.84, P < 0.0001) but less well with DECT (for index tophi, r(s) = 0.46, P = 0.004 for both). Large variation was observed in the amount of urate deposits documented by DECT in tophi of similar physical size.
CONCLUSIONS: Dual-energy computed tomography scanning is a highly reproducible method for measuring urate deposits within tophi. This imaging modality reveals the composition of tophi that contain variable urate deposits embedded within soft tissue.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22157268     DOI: 10.1097/RHU.0b013e31823e5cda

Source DB:  PubMed          Journal:  J Clin Rheumatol        ISSN: 1076-1608            Impact factor:   3.517


  17 in total

1.  Imaging: Dual-energy CT useful when assessing tophaceous gout.

Authors:  Katrina Ray
Journal:  Nat Rev Rheumatol       Date:  2012-01-17       Impact factor: 20.543

Review 2.  Imaging in gout: A review of the recent developments.

Authors:  Priya Varghese Chowalloor; Teck K Siew; Helen Isobel Keen
Journal:  Ther Adv Musculoskelet Dis       Date:  2014-08       Impact factor: 5.346

Review 3.  An old disease with new insights: Update on diagnosis and treatment of gout.

Authors:  Berivan Bitik; M Akif Öztürk
Journal:  Eur J Rheumatol       Date:  2014-06-01

4.  2012 American College of Rheumatology guidelines for management of gout. Part 1: systematic nonpharmacologic and pharmacologic therapeutic approaches to hyperuricemia.

Authors:  Dinesh Khanna; John D Fitzgerald; Puja P Khanna; Sangmee Bae; Manjit K Singh; Tuhina Neogi; Michael H Pillinger; Joan Merill; Susan Lee; Shraddha Prakash; Marian Kaldas; Maneesh Gogia; Fernando Perez-Ruiz; Will Taylor; Frédéric Lioté; Hyon Choi; Jasvinder A Singh; Nicola Dalbeth; Sanford Kaplan; Vandana Niyyar; Danielle Jones; Steven A Yarows; Blake Roessler; Gail Kerr; Charles King; Gerald Levy; Daniel E Furst; N Lawrence Edwards; Brian Mandell; H Ralph Schumacher; Mark Robbins; Neil Wenger; Robert Terkeltaub
Journal:  Arthritis Care Res (Hoboken)       Date:  2012-10       Impact factor: 4.794

Review 5.  Peering through the glare: using dual-energy CT to overcome the problem of metal artefacts in bone radiology.

Authors:  Tyler M Coupal; Paul I Mallinson; Patrick McLaughlin; Savvas Nicolaou; Peter L Munk; Hugue Ouellette
Journal:  Skeletal Radiol       Date:  2014-01-17       Impact factor: 2.199

Review 6.  Dual-energy computed tomography for gout diagnosis and management.

Authors:  Nicola Dalbeth; Hyon K Choi
Journal:  Curr Rheumatol Rep       Date:  2013-01       Impact factor: 4.592

7.  The effect of tube voltage combination on image artefact and radiation dose in dual-source dual-energy CT: comparison between conventional 80/140 kV and 80/150 kV plus tin filter for gout protocol.

Authors:  Ji Young Jeon; Sheen-Woo Lee; Yu Mi Jeong; Han Joo Baek
Journal:  Eur Radiol       Date:  2018-07-09       Impact factor: 5.315

Review 8.  The gouty tophus: a review.

Authors:  Ashika Chhana; Nicola Dalbeth
Journal:  Curr Rheumatol Rep       Date:  2015-03       Impact factor: 4.592

9.  Methods of assessment of tophus and bone erosions in gout using dual-energy CT: reproducibility analysis.

Authors:  Dan Shi; Jian-Xia Xu; Hua-Xiang Wu; Ying Wang; Qi-Jing Zhou; Ri-Sheng Yu
Journal:  Clin Rheumatol       Date:  2014-06-17       Impact factor: 2.980

10.  The application of dual-energy computed tomography in the diagnosis of acute gouty arthritis.

Authors:  Huaxiang Wu; Jing Xue; Lu Ye; Qijing Zhou; Dan Shi; Rongzhen Xu
Journal:  Clin Rheumatol       Date:  2014-04-18       Impact factor: 2.980

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.