Literature DB >> 22156009

Simultaneous bilateral contrast injection in computed tomography pulmonary angiography.

Stefan Bulla1, Gregor Pache, Thorsten Bley, Mathias Langer, Philipp Blanke.   

Abstract

BACKGROUND: Computed tomography pulmonary angiography (CTPA) has evolved as the gold standard for diagnosing pulmonary embolism. However, subsegmental arteries are often not assessed to do insufficient attenuation.
PURPOSE: To evaluate the influence of simultaneous bilateral versus unilateral injection of a fixed amount of contrast media on pulmonary artery opacification and image quality in CTPA.
MATERIAL AND METHODS: In this institutional review board-approved prospective study, 180 patients (91 women, mean age 61.9 ± 16.5 years) referred for CTPA (100 kV) due to suspected pulmonary embolism were randomized in groups of 45 patients each, with either unilateral (A:4 mL/s; B:6 mL/s) or bilateral (C: 6 mL/s; D: 8 mL/s) (Y-shaped line) injection of 50 mL contrast media. Attenuation was assessed including the subsegmental arteries (4th order). Image quality was evaluated by two readers in consensus using a three-point grading scale (3 = excellent image quality, no artifacts, 1 = non-diagnostic).
RESULTS: Mean pulmonary artery attenuation was significantly higher with bilateral injection (1st to 3rd order: A: 303.6 ± 8.8HU; B: 371.1 ± 11.0HU vs. C: 443.2 ± 24.1HU; D: 562.3 ± 15.3HU, P < 0.001). Evaluation of subsegmental arteries was feasible for all patients in groups B-D, but only in 36/45 (80%) patients in group A. Subsegmental attenuation was significantly higher with bilateral injection (A: 284.7 ± 12.1HU; B: 367.4 ± 12.1HU vs. C: 494.2 ± 21.5HU; D: 562.3 ± 26.7HU, P < 0.001). Image quality was diagnostic for all patients but best for group C (A: 2.15 ± 0.4; B: 2.14 ± 0.5; C: 2.92 ± 0.3, and D: 2.51 ± 0.5).
CONCLUSION: Using the same amount of contrast media, bilateral injection yields higher pulmonary artery attenuation and better image quality than unilateral injection. This technique may improve subsegmental pulmonary artery assessment.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22156009     DOI: 10.1258/ar.2011.110244

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  3 in total

1.  Pulmonary CTA in sickle cell patients: quantitative assessment of enhancement quality.

Authors:  Jeff Jensen; Tony Lin; Elliot K Fishman; Pamela T Johnson
Journal:  Emerg Radiol       Date:  2017-08-11

2.  Determination of lowest possible contrast volume in computed tomography pulmonary angiography by using pulmonary transit time.

Authors:  Koray Kilic; Gonca Erbas; Murat Ucar; Koray Akkan; Nil Tokgoz; Mehmet Arac; Sedat Isik
Journal:  Jpn J Radiol       Date:  2014-01-05       Impact factor: 2.374

3.  Relationship between low tube voltage (70 kV) and the iodine delivery rate (IDR) in CT angiography: An experimental in-vivo study.

Authors:  Michael M Lell; Ulrike Fleischmann; Hubertus Pietsch; Johannes G Korporaal; Ulrike Haberland; Andreas H Mahnken; Thomas G Flohr; Michael Uder; Gregor Jost
Journal:  PLoS One       Date:  2017-03-20       Impact factor: 3.240

  3 in total