Literature DB >> 22153644

Spectral-domain optical coherence tomography for early glaucoma assessment: analysis of macular ganglion cell complex versus peripapillary retinal nerve fiber layer.

Pilar A M Moreno1, Bruno Konno, Verônica Castro Lima, Dinorah P E Castro, Leonardo Cunha Castro, Mauro Toledo Leite, Maria A M Mendes Pacheco, Jae Min Lee, Tiago Santos Prata.   

Abstract

OBJECTIVE: We sought to compare the glaucoma discrimination ability of macular inner retinal layer (MIRL) thickness with that of conventional peripapillary retinal nerve fiber layer (pRNFL) thickness as measured by spectral-domain optical coherence tomography (SD-OCT) in patients with early glaucoma.
DESIGN: Cross-sectional study. PARTICIPANTS: We studied 67 patients with early glaucoma (visual field mean deviation index ≥-6 dB), and 56 healthy subjects were prospectively enrolled.
METHODS: All patients underwent MIRL thickness measurement (ganglion cell complex [GCC] scan) and pRNFL thickness measurement (3.45 mm scan) by SD-OCT. Whenever both eyes were eligible, one was randomly selected. Receiver operating characteristic curves and sensitivities at fixed specificities were generated for different parameters. The areas under the receiver operating characteristic curves (AUCs) of each parameter were compared.
RESULTS: The average mean deviation for the glaucomatous eyes was -2.5 ± 1.6 dB. The AUCs for average (0.815); superior (0.807); and inferior (0.788) MIRL thicknesses were not significantly different (p ≥ 0.18). The AUCs for average (0.735); superior (0.728); and inferior (0.697) pRNFL thicknesses were also similar (p ≥ 0.15). Average MIRL thickness had a significantly larger AUC compared to average pRNFL thickness analysis (0.815 vs 0.735; p = 0.03). Sensitivities at 80% specificity for average MIRL and pRNFL thicknesses were 66.7% (cutoff, 89.9 μm) and 62.9% (cutoff, 111.8 μm), respectively.
CONCLUSIONS: The GCC scan showed a similar or even a slightly better ability to discriminate between healthy and early glaucomatous eyes compared to the pRNFL scan. Different from previous analyses considering total macular thickness, the GCC macular scan seems to be a useful tool for identification of early structural damage in patients with glaucoma.
Copyright © 2011 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22153644     DOI: 10.1016/j.jcjo.2011.09.006

Source DB:  PubMed          Journal:  Can J Ophthalmol        ISSN: 0008-4182            Impact factor:   1.882


  27 in total

Review 1.  In vivo imaging methods to assess glaucomatous optic neuropathy.

Authors:  Brad Fortune
Journal:  Exp Eye Res       Date:  2015-06-03       Impact factor: 3.467

Review 2.  Parameters of ocular fundus on spectral-domain optical coherence tomography for glaucoma diagnosis.

Authors:  Yu-Lin Tao; Li-Ming Tao; Zheng-Xuan Jiang; He-Ting Liu; Kun Liang; Mo-Han Li; Xuan-Sheng Zhu; Yan-Lin Ren; Bing-Jie Cui
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

3.  Comparison of different spectral domain OCT scanning protocols for diagnosing preperimetric glaucoma.

Authors:  Renato Lisboa; Augusto Paranhos; Robert N Weinreb; Linda M Zangwill; Mauro T Leite; Felipe A Medeiros
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-05-13       Impact factor: 4.799

4.  Relation between macular retinal ganglion cell/inner plexiform layer thickness and multifocal electroretinogram measures in experimental glaucoma.

Authors:  Xunda Luo; Nimesh B Patel; Lakshmi P Rajagopalan; Ronald S Harwerth; Laura J Frishman
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-06-26       Impact factor: 4.799

5.  Sensitivity and specificity of the iVue iWellnessExam™ in detecting retinal and optic nerve disorders.

Authors:  Catherine Awad; Samantha Slotnick; Sanjeev Nath; Jerome Sherman
Journal:  Eye Brain       Date:  2013-02-13

6.  Evaluating glaucoma damage: emerging imaging technologies.

Authors:  Tigran Kostanyan; Gadi Wollstein; Joel S Schuman
Journal:  Expert Rev Ophthalmol       Date:  2015-02-09

7.  Optical coherence tomography study of experimental anterior ischemic optic neuropathy and histologic confirmation.

Authors:  Joyce K Ho; Madison P Stanford; Mohammad A Shariati; Roopa Dalal; Yaping Joyce Liao
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-09-05       Impact factor: 4.799

8.  Association between ganglion cell complex and axial length.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji
Journal:  Jpn J Ophthalmol       Date:  2013-06-08       Impact factor: 2.447

Review 9.  Optic nerve head and fibre layer imaging for diagnosing glaucoma.

Authors:  Manuele Michelessi; Ersilia Lucenteforte; Francesco Oddone; Miriam Brazzelli; Mariacristina Parravano; Sara Franchi; Sueko M Ng; Gianni Virgili
Journal:  Cochrane Database Syst Rev       Date:  2015-11-30

Review 10.  Macular imaging with optical coherence tomography in glaucoma.

Authors:  Vahid Mohammadzadeh; Nima Fatehi; Adeleh Yarmohammadi; Ji Woong Lee; Farideh Sharifipour; Ramin Daneshvar; Joseph Caprioli; Kouros Nouri-Mahdavi
Journal:  Surv Ophthalmol       Date:  2020-03-19       Impact factor: 6.048

View more