Is there an underestimation of intima-media thickness based on M-mode ultrasound technique in the abdominal aorta?

Elsa M Dahlén1, Thomas Andreasson, Magnus Cinthio, Fredrik H Nystrom, Carl Johan Östgren, Toste Länne.   

Abstract

Measuring intima-media thickness (IMT) in the common carotid artery (CCA) is a valuable resource for the evaluation of subclinical atherosclerosis. The main objective of this study was to explore whether a B-mode ultrasound technique, Philips ATL, and an M-mode ultrasound technique, Wall Track System (WTS), show interchangeable results when measured in CCA and the abdominal aorta (AA). A total of 24 healthy, young subjects were examined. IMT and lumen diameter (LD) of the AA and the CCA were measured twice by two skilled ultrasonographers with two different ultrasound equipment B-mode: (Philips, ATL and M-mode: WTS).The intra-observer variability of IMT in CCA and AA using B-mode showed a coefficient of variation 8% and 9%, and with M-mode 11% and 15%, respectively. Interobserver variability of IMT in CCA and AA using B-mode was 6% and 12%, and with M-mode 11% and 18%, respectively. CCA IMT was 0·53 ± 0·07 and 0·53 ± 0·09 mm using B-mode and M-mode, respectively. However, in AA, IMT was 0·61 ± 0·05 and 0·54 ± 0·10 mm using B-mode and M-mode, respectively. Thus, AA IMT was 11·5% thicker using B-mode (P < 0·01). We received adequate IMT readings from the carotid artery as well as the AA using two commonly used B-mode and M-mode techniques. B-mode technique seems to show less variability, especially in the AA. More importantly, the two techniques measured different IMT thickness in the aorta, emphasizing the importance of using similar technique when comparing the impact of absolute values of IMT on cardiovascular disease.
© 2011 The Authors. Clinical Physiology and Functional Imaging © 2011 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

Entities:  

Mesh:

Year:  2011        PMID: 22152072     DOI: 10.1111/j.1475-097X.2011.01045.x

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  2 in total

1.  Intima-media thickness of the descending aorta in patients with bicuspid aortic valve.

Authors:  Johan Petrini; Mohamed Yousry; Per Eriksson; Hanna M Björk; Anette Rickenlund; Anders Franco-Cereceda; Kenneth Caidahl; Maria J Eriksson
Journal:  Int J Cardiol Heart Vasc       Date:  2016-04-02

2.  Ultrasonographic Study of the Effects of Essential Hypertension on the Luminal Diameter and Doppler Velocimetric Indices of the Abdominal Aorta in Adults.

Authors:  John Oluwafemi Adetokunbo; Bolanle Olubunmi Ibitoye; Anthony Olubunmi Akintomide; Bukunmi Michael Idowu
Journal:  J West Afr Coll Surg       Date:  2022-08-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.