Literature DB >> 22150633

Measurement of effective aortic valve area using three-dimensional echocardiography in children undergoing aortic balloon valvuloplasty for aortic stenosis.

Tara Bharucha1, Fernanda Fernandes, Cameron Slorach, Luc Mertens, Mark Kevin Friedberg.   

Abstract

AIMS: Pressure gradient is used for timing of balloon aortic valvuloplasty for aortic stenosis (AS) in children, but does not correlate well with outcome and is limited if ventricular function is poor. In adults, effective orifice area (EOA) is used to assess AS severity, but EOA by continuity equation or 2D echo is unreliable in children. Three-dimensional echocardiography (3DE) may reliably assess EOA but has not been studied in children. We assessed measurement of aortic valve EOA by 3DE in children with AS before and after balloon aortic valvuloplasty and compared results with change in aortic valve gradient.
METHODS: 3DE was performed at time of catheterization before and after balloon aortic valvuloplasty. Using 3DE multiplanar review mode, valve annulus diameter, area, and EOA were measured and compared with change in aortic gradient and degree of aortic insufficiency.
RESULTS: Twenty-four 3DE studies in 12 children (mean age 4.4 ± 5.0 years) were analyzed. EOA was measurable in all. Catheter peak gradient decreased from 45 ± 10 to 26 ± 17 mmHg (P = 0.0018). 3DE EOA increased after balloon aortic valvuloplasty (0.59 ± 0.52 cm(2) vs 0.80 ± 0.70 cm(2) ; P = 0.03), without change in valve diameter. EOA change correlated with change in peak (r = 0.77; P = 0.005) and mean (r = 0.60; P = 0.03) aortic valve gradient post balloon aortic valvuloplasty.
CONCLUSION: 3DE facilitates EOA measurement in pediatric AS and correlates with change in aortic valve gradient after balloon valvuloplasty.
© 2011, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22150633     DOI: 10.1111/j.1540-8175.2011.01595.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

1.  Non-Invasive Imaging for Congenital Heart Disease: Recent Innovations in Transthoracic Echocardiography.

Authors:  Martin Koestenberger; Mark K Friedberg; William Ravekes; Eirik Nestaas; Georg Hansmann
Journal:  J Clin Exp Cardiolog       Date:  2012-01-22

2.  Usefulness of Three-Dimensional Transthoracic Echocardiographic Planimetry in a 4-Month-Old Infant with Comorbid Aortic Stenosis and Coarctation of the Aorta Complicated with Low Left Ventricular Ejection Fraction.

Authors:  Junpei Kawamura; Kentaro Ueno; Yoshihiro Takahashi; Naohiro Shiokawa; Daisuke Hazeki; Yasuhiro Okamoto
Journal:  CASE (Phila)       Date:  2022-07-02
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.