Literature DB >> 22149922

Influence of various types of damage on the fracture strength of ceramic femoral heads.

Viola Wuttke1, Hartmut Witte, Katrin Kempf, Thomas Oberbach, Daniel Delfosse.   

Abstract

Ceramic-on-ceramic articulations are a frequently used bearing for total hip replacements. This success mainly is due to their excellent tribological properties. Ceramics can withstand high pressure loads due to its brittleness but only low bending stresses. A ceramic ball head fracture is the result of subcritical crack growth. This kind of fracture in vivo can abet by damage or contamination of the stem cone. The main goal of this work is to provide a risk assessment of different possible damage mechanisms and contaminations that may result in lower fracture strength of a ceramic ball head. To simulate potential causes, different types and dimensions of metal wire, foils, hair, and lubricants were inserted between the ceramic ball head and the metal cone of the stem. The test results clearly show that fracture strength is negatively influenced by most of the inhomogeneities between the cone and the head because they increase the peak stresses acting on a part of the ceramic ball head. The results of this article clearly confirm the demand for an undamaged taper fit "free of contamination" between the ceramic head and the metal cone during implantation.

Entities:  

Mesh:

Year:  2011        PMID: 22149922     DOI: 10.1515/BMT.2011.026

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  5 in total

Review 1.  Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.

Authors:  Michael Morlock; Dennis Bünte; Julian Gührs; Nicholas Bishop
Journal:  HSS J       Date:  2016-09-20

2.  Two-year follow-up of revision total hip arthroplasty using a ceramic revision head with a retained well-fixed femoral component: a case series.

Authors:  Dirk Ganzer; Lutz Forke; Ulrich Irlenbusch
Journal:  J Med Case Rep       Date:  2014-12-17

3.  Third-generation pure alumina and alumina matrix composites in total hip arthroplasty: What is the evidence?

Authors:  Didier Hannouche; Matthieu Zingg; Hermes Miozzari; Remy Nizard; Anne Lübbeke
Journal:  EFORT Open Rev       Date:  2018-01-10

4.  Influence of Different Damage Patterns of the Stem Taper on Fixation and Fracture Strength of Ceramic Ball Heads for Total Hip Replacement.

Authors:  Danny Vogel; Jessica Hembus; Mario Jackszis; Vera Bolte; Rainer Bader
Journal:  Biomed Res Int       Date:  2020-05-13       Impact factor: 3.411

5.  Are asymmetric metal markings on the cone surface of ceramic femoral heads an indication of entrapped debris?

Authors:  Sebastian Valet; Bernhard Weisse; Jakob Kuebler; Martin Zimmermann; Christian Affolter; Giovanni Pietro Terrasi
Journal:  Biomed Eng Online       Date:  2014-04-04       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.