Literature DB >> 22147832

Diagnostic performance of percutaneous core-needle lung biopsy under CT scan fluoroscopic guidance for pulmonary lesions measuring ≤10 mm.

Yoshikane Yamauchi1, Yotaro Izumi2, Seishi Nakatsuka3, Masanori Inoue3, Yuichiro Hayashi4, Mitsutomo Kohno1, Takashi Ohtsuka1, Masaki Anraku1, Taichiro Goto1, Hiroaki Nomori1.   

Abstract

Entities:  

Mesh:

Year:  2011        PMID: 22147832     DOI: 10.1378/chest.11-1821

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


× No keyword cloud information.
  9 in total

Review 1.  Updates in percutaneous lung biopsy: new indications, techniques and controversies.

Authors:  Jonathan M Lorenz
Journal:  Semin Intervent Radiol       Date:  2012-12       Impact factor: 1.513

2.  Circulating Genetically Abnormal Cells Add Non-Invasive Diagnosis Value to Discriminate Lung Cancer in Patients With Pulmonary Nodules ≤10 mm.

Authors:  Maosong Ye; Xiaoxuan Zheng; Xin Ye; Juncheng Zhang; Chuoji Huang; Zilong Liu; Meng Huang; Xianjun Fan; Yanci Chen; Botao Xiao; Jiayuan Sun; Chunxue Bai
Journal:  Front Oncol       Date:  2021-03-11       Impact factor: 6.244

Review 3.  Navigational bronchoscopy with biopsy versus computed tomography-guided biopsy for the diagnosis of a solitary pulmonary nodule: a cost-consequences analysis.

Authors:  Christopher R Dale; David K Madtes; Vincent S Fan; Jed A Gorden; David L Veenstra
Journal:  J Bronchology Interv Pulmonol       Date:  2012-10

4.  Detection of circulating genetically abnormal cells using 4-color fluorescence in situ hybridization for the early detection of lung cancer.

Authors:  Mingxiang Feng; Xin Ye; Baishen Chen; Juncheng Zhang; Chuoji Huang; Chunxue Bai; Miao Lin; Haining Zhou; Meng Huang; Yanci Chen; Yunhe Zhu; Botao Xiao; Ruth L Katz
Journal:  J Cancer Res Clin Oncol       Date:  2021-02-06       Impact factor: 4.553

5.  Lung Cancer Diagnosis by Fine Needle Aspiration Is Associated With Reduction in Resection of Nonmalignant Lung Nodules.

Authors:  Julie A Barta; Claudia I Henschke; Raja M Flores; Rowena Yip; David F Yankelevitz; Charles A Powell
Journal:  Ann Thorac Surg       Date:  2017-03-06       Impact factor: 5.102

6.  CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy.

Authors:  Juliano Ribeiro de Andrade; Rafael Dahmer Rocha; Priscila Mina Falsarella; Antonio Rahal Junior; Ricardo Sales Dos Santos; Juliana Pereira Franceschini; Hiran Chrishantha Fernando; Rodrigo Gobbo Garcia
Journal:  J Bras Pneumol       Date:  2018 Jul-Aug       Impact factor: 2.624

7.  Non-diagnostic Results of Percutaneous Transthoracic Needle Biopsy: A Meta-analysis.

Authors:  Kum Ju Chae; Hyunsook Hong; Soon Ho Yoon; Seokyung Hahn; Gong Yong Jin; Chang Min Park; Jin Mo Goo
Journal:  Sci Rep       Date:  2019-08-27       Impact factor: 4.379

8.  Detection of circulating genetically abnormal cells in peripheral blood for early diagnosis of non-small cell lung cancer.

Authors:  Wei-Ran Liu; Bin Zhang; Chen Chen; Yue Li; Xin Ye; Dong-Jiang Tang; Jun-Cheng Zhang; Jing Ma; Yan-Ling Zhou; Xian-Jun Fan; Dong-Sheng Yue; Chen-Guang Li; Hua Zhang; Yu-Chen Ma; Yan-Song Huo; Zhen-Fa Zhang; Shu-Yu He; Chang-Li Wang
Journal:  Thorac Cancer       Date:  2020-09-28       Impact factor: 3.500

9.  Feasibility of combined optical coherence tomography and autofluorescence imaging for visualization of needle biopsy placement.

Authors:  Geoffrey Hohert; Renelle Myers; Sylvia Lam; Andrei Vertikov; Anthony Lee; Stephen Lam; Pierre Lane
Journal:  J Biomed Opt       Date:  2020-10       Impact factor: 3.170

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.