Literature DB >> 22146552

Outcomes of Descemet stripping automated endothelial keratoplasty in patients with previous glaucoma drainage device insertion.

Peter Kim1, Maoz D Amiran, Alejandro Lichtinger, Sonia N Yeung, Allan R Slomovic, David S Rootman.   

Abstract

PURPOSE: To report the outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with a previously inserted glaucoma drainage device (GDD).
METHODS: The clinical records of patients who had DSAEK surgery with a history of GDD insertion were reviewed.
RESULTS: Eleven eyes of 10 patients (7 men and 3 women) were included. The mean age for DSAEK surgery was 67.2 ± 20.4 years (range, 22-93 years). The mean follow-up after DSAEK surgery was 20.2 ± 10.7 months (range, 3-37 months). Preoperative mean logarithm of the minimum angle of resolution (logMAR)-corrected distance visual acuity was 1.8 ± 0.6 (range, 20/100 to hand motions), and this improved to 0.9 ± 0.8 (range, 20/40 to hand motions) at the final follow-up (P < 0.01). There was no statistical difference in mean pre-DSAEK versus final post-DSAEK intraocular pressure (P = 0.88). Six of 11 eyes (54.5%) had double GDD insertion before DSAEK surgery. GDD tubes were trimmed in 6 eyes (54.5%), and no eyes required further glaucoma surgical intervention after DSAEK surgery. Postoperative complications included early postoperative graft dislocation in 4 eyes (36.4%) that were successfully repositioned. Four eyes (36.4%) had an episode of endothelial rejection, with 2 patients (18.2%) requiring repeat endothelial keratoplasty for endothelial failure. The mean donor endothelial cell count was 2740 cell per square millimeter preoperatively and reduced to 858 cells per square millimeter at the final follow-up, a significant mean reduction of 69%. This was significantly greater than previously reported endothelial cell loss after DSAEK alone at our institution.
CONCLUSIONS: Although surgery may be more challenging, the presence of GDD is not a contraindication to DSAEK surgery. In this series, there was a high rate of dislocation that was successfully managed with rebubbling. DSAEK seems to be a reasonable alternative to penetrating keratoplasty for corneal decompensation after GDD.

Entities:  

Mesh:

Year:  2012        PMID: 22146552     DOI: 10.1097/ICO.0b013e318224820a

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  14 in total

1.  Outcome of Descemet stripping automated endothelial keratoplasty in eyes with an Ahmed glaucoma valve.

Authors:  Patrick J Chiam; Robert Cheeseman; Vivian W Ho; Vito Romano; Anshoo Choudhary; Mark Batterbury; Stephen B Kaye; Colin E Willoughby
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-03-17       Impact factor: 3.117

2.  Outcomes of Descemet Membrane Endothelial Keratoplasty in Patients With Previous Glaucoma Surgery.

Authors:  Carolina Aravena; Fei Yu; Sophie X Deng
Journal:  Cornea       Date:  2017-03       Impact factor: 2.651

3.  Comparison of graft survival following penetrating keratoplasty and Descemet's stripping endothelial keratoplasty in eyes with a glaucoma drainage device.

Authors:  Shawn M Iverson; Oriel Spierer; George C Papachristou; William J Feuer; Wei Shi; David S Greenfield; Terrence P O'Brien
Journal:  Int Ophthalmol       Date:  2017-03-16       Impact factor: 2.031

4.  Management of detached graft donor by SF₆ injection following Descemet stripping automated endothelial keratoplasty of an eye with iridocorneal endothelial syndrome and Ahmed glaucoma drainage tube.

Authors:  Kansu Tahir Bozkurt; Banu Torun Acar; Suphi Acar
Journal:  Int Ophthalmol       Date:  2012-07-01       Impact factor: 2.031

Review 5.  Glaucoma management after corneal transplantation surgeries.

Authors:  Helen L Kornmann; Steven J Gedde
Journal:  Curr Opin Ophthalmol       Date:  2016-03       Impact factor: 3.761

6.  Modified Descemet's stripping automated endothelial keratoplasty for eyes with glaucoma drainage devices and shallow anterior chambers.

Authors:  Alfonso Vasquez-Perez; Syed Mohammed Naqib; Mayank A Nanavaty
Journal:  Int Ophthalmol       Date:  2017-07-03       Impact factor: 2.031

Review 7.  Ahmed glaucoma valve implant: surgical technique and complications.

Authors:  Ivano Riva; Gloria Roberti; Francesco Oddone; Anastasios Gp Konstas; Luciano Quaranta
Journal:  Clin Ophthalmol       Date:  2017-02-17

8.  Spontaneous reattachment of a posteriorly dislocated endothelial graft: a case report.

Authors:  Ka Wai Kam; Alvin L Young
Journal:  Case Rep Transplant       Date:  2013-03-03

9.  New continuous air pumping technique to improve clinical outcomes of descemet-stripping automated endothelial keratoplasty in asian patients with previous ahmed glaucoma valve implantation.

Authors:  Chang-Min Liang; Yi-Hao Chen; Da-Wen Lu; Jiann-Torng Chen; Ming-Cheng Tai
Journal:  PLoS One       Date:  2013-08-16       Impact factor: 3.240

10.  De novo ocular hypertension after Descemet stripping endothelial keratoplasty: comparative 3-year incidence, risk factors, and outcomes.

Authors:  Errol W Chan; Tina T Wong; Hla M Htoon; Ching L Ho; Donald T Tan; Jodhbir S Mehta
Journal:  Clin Ophthalmol       Date:  2013-09-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.