Literature DB >> 22146383

Salvage of failed trochanteric fracture fixation using the Revitan curved cementless modular hip arthroplasty.

Amr A K H Abouelela1.   

Abstract

Failed internal fixation of an intertrochanteric or subtrochanteric fracture often leads to persistent pain and diminished function. This study evaluated 16 patients treated with Revitan curved cementless modular stem (Zimmer GmbH, Winterthur, Switzerland). At a mean follow-up period of 60 months, all patients demonstrated clinically significant pain relief and return to ambulation after salvage total hip arthroplasty. Mean Harris Hip Score improved from 17.8 to 87.7 points postoperatively. Radiographic follow-up demonstrated stable stem and bony ingrowth in 16 patients without evidence of subsidence. Eight patients had slight awareness of lateral trochanteric pain with no compromise of activities, and 1 patient had nonunion of the greater trochanter. Revitan curved cementless modular stem represents a useful treatment option in salvage total hip arthroplasty of failed pertrochanteric fixation.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22146383     DOI: 10.1016/j.arth.2011.10.021

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Salvage of failed hip osteosynthesis for fractures with modular hip prosthesis.

Authors:  Panagiotis K Karampinas; George Kollias; John Vlamis; Eustratios A Papadelis; Spiros G Pneumaticos
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-03-10

2.  Augmentation of implant fixation in osteoporotic bone.

Authors:  Clifford B Jones
Journal:  Curr Osteoporos Rep       Date:  2012-12       Impact factor: 5.096

3.  A systematic review and meta-analysis of complications in conversion arthroplasty methods for failed intertrochanteric fracture fixation.

Authors:  Daniel B Dix; Ibukunoluwa B Araoye; Jackson R Staggers; Chee P Lin; Ashish B Shah; Amit Kumar Agarwal; Sameer M Naranje
Journal:  J Clin Orthop Trauma       Date:  2018-02-21

4.  Clinical outcome of endoprosthetic replacement for failed treatment of intertrochanteric fractures: A retrospective case series.

Authors:  Wei Feng; Ting Hao; Wan-Lin Liu; Yan-Fei Jia; Zeng-Tao Hao; Sheng-Bin Bai
Journal:  Pak J Med Sci       Date:  2013-04       Impact factor: 1.088

5.  Case series and finite element analysis of PFNA combined with cerclage wire for treatment of subtrochanteric fracture of femur.

Authors:  Xiaowei Huang; Fangxue Zhang; Yong Zhang
Journal:  J Orthop Surg Res       Date:  2021-01-20       Impact factor: 2.359

6.  Treatment of Osteoarthritis Secondary to Severe Coxa Vara with Modular Total Hip Arthroplasty.

Authors:  Bohan Zhang; Jingyang Sun; Yinqiao Du; Junmin Shen; Tiejian Li; Yonggang Zhou
Journal:  Ther Clin Risk Manag       Date:  2021-11-19       Impact factor: 2.423

7.  The role of internal fixation in the treatment of femoral head necrosis with ipsilateral hip fracture.

Authors:  Xinguo Zhang; Sikai Liu
Journal:  Medicine (Baltimore)       Date:  2022-08-12       Impact factor: 1.817

8.  Salvage of failed trochanteric and subtrochanteric fractures using a distally fixed, modular, uncemented hip revision stem.

Authors:  Rüdiger J Weiss; Johan Kärrholm; Nils P Hailer; Mats O Beckman; André Stark
Journal:  Acta Orthop       Date:  2012-10       Impact factor: 3.717

9.  Breakage of a third generation gamma nail: a case report and review of the literature.

Authors:  Takashi Iwakura; Takahiro Niikura; Sang Yang Lee; Yoshitada Sakai; Kotaro Nishida; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Case Rep Orthop       Date:  2013-05-20
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.