A retrieval analysis of explanted Durom metal-on-metal hip arthroplasties.

Ashley K Matthies1, Johann Henckel, John A Skinner, Alister J Hart.   

Abstract

Given the recent reports of high failure rates, an improved understanding of the mechanism of failure of large diameter metal-on-metal hip arthroplasties is essential. We present clinical data and tribological analysis of a consecutive series of 74 failed large diameter metal-on-metal hips, comparing the Durom (Zimmer) with the Birmingham hip resurfacing (BHR) (Smith and Nephew). We retrospectively analysed pre-, intra-, and post-operative clinical data and measured the linear wear and component form of the explanted components using a roundness measuring machine. A significantly higher proportion of hips in the Durom group failed as a result of acetabular loosening (p=0.001) and this was supported by evidence of reduced bone in-growth on the backside of the cup. Comparison of roundness measurement revealed that the Durom hip was significantly lower wearing than the BHR (p<0.05) but the Durom femoral components were subject to significantly greater form errors (p<0.001), the pole of the head being flattened by up to 31 microns. Although the Durom hip is low wearing, reduced sphericity of the femoral component may have resulted in equatorial bearing, leading to an increased frictional torque at the cup-bone interface, preventing bone in-growth, and culminating in acetabular loosening. This supports recent clinical findings of high revision rates as a result of acetabular loosening for the Durom metal-on-metal hip system.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22144337     DOI: 10.5301/HIP.2011.8885

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  4 in total

1.  Correlation between groin pain and cup design of hip-resurfacing implants: a prospective study.

Authors:  Julien Girard; Erwan Pansard; Reda Ouahes; Henri Migaud; Cyril Delay; Laurent Vasseur
Journal:  Int Orthop       Date:  2013-12-10       Impact factor: 3.075

2.  Does diametrical clearance influence the wear of Pinnacle hip implants?

Authors:  Sean Bergiers; Harry Hothi; Johann Henckel; Antti Eskelinen; John Skinner; Alister Hart
Journal:  Bone Joint Res       Date:  2020-08-25       Impact factor: 5.853

3.  Metal on metal total hip arthroplasty and a large groin mass: Not always adverse reaction to metallic debris.

Authors:  Harry Krishnan; Alex Magnussen; Aadhar Sharma; John Skinner
Journal:  Int J Surg Case Rep       Date:  2014-12-08

4.  3D patient imaging and retrieval analysis help understand the clinical importance of rotation in knee replacements.

Authors:  Arianna Cerquiglini; Johann Henckel; Harry Hothi; Niccoló Rotigliano; Michael T Hirschmann; Alister J Hart
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-03-08       Impact factor: 4.342

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.