Literature DB >> 22143046

Quantitative volumetry of cement leakage in viscosity-controlled vertebroplasty.

Michaela Gstöttner1, Alexandra Angerer, Rafal Rosiek, Christian Michael Bach.   

Abstract

STUDY
DESIGN: This study was designed as a cohort study comparing a prospective sample to a historic control group.
OBJECTIVE: The aim of the actual trial was to compare the rate of cement leakage by quantitative volumetry comparing viscosity-controlled and non-viscosity-controlled vertebroplasty. SUMMARY OF BACKGROUND DATA: Percutaneous vertebroplasty (PVP) is a widespread safe and effective technique in the treatment of osteoporotic compression fractures and vertebral metastatic lesions. However, cement leakage has been identified as a problem of this technique. The leakage rates are reported to range from 7% to 90%. The main influence factor for leakage has been demonstrated to be cement viscosity. Assessment of appropriate injection viscosity is highly subjective and observer dependent. Viscosity-controlled vertebroplasty (Vertecem system) has been developed to objectively measure cement viscosity before injection. It introduces a viscosimeter to measure the actual cement viscosity before injection into the vertebra, and therefore may prevent leakages resulting from low-viscosity cement injections. Despite more than 800 Pubmed citations on PVP, there is only 1 report on distinct measurement of cement leakage by semiquantitative volumetry.
METHODS: A total of 111 vertebrae in 68 patients, in which PVP was performed for osteoporotic fractures, were included. Thirty-seven patients (76 operated vertebrae) were assessed prospectively using the viscosity-controlled vertebroplasty. The results were compared with a retrospective group of 31 patients (35 operated vertebrae) undergoing PVP without using a viscosimeter.
RESULTS: : There were no significant differences between the 2 groups in the applied volume of cement per fractured vertebra (P=0.73). The frequency of cement leakage in viscosimete-assisted vertebroplasty was 42.1% and 58.3% in the historic group. Cement leakage into the basivertebral vein (type B), was detected in 6.6% with and in 11.1% without viscosimetry.
CONCLUSIONS: The use of viscosity-controlled vertebroplasty led to a decrease in the leakage rate from 58.3% to 42.1%. Leakage into the basivertebral vein with the risk of compression of nerval structures was reduced to almost 50% when viscosimetry was performed. It revealed to be a helpful tool for more unexperienced surgeons to assess the appropriate viscosity for vertebroplasty.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22143046     DOI: 10.1097/BSD.0b013e31823f62b1

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  9 in total

1.  Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients.

Authors:  Si-Yuan Zhu; Zhao-Ming Zhong; Qian Wu; Jian-Ting Chen
Journal:  Int Orthop       Date:  2016-01-12       Impact factor: 3.075

2.  Risk factors for predicting cement leakage following percutaneous vertebroplasty for osteoporotic vertebral compression fractures.

Authors:  Jie Ding; Qiong Zhang; Jianfei Zhu; Weiwei Tao; Qi Wu; Lu Chen; Pengwen Shi; Haojie Zhang
Journal:  Eur Spine J       Date:  2015-04-08       Impact factor: 3.134

Review 3.  What's new in vertebral cementoplasty?

Authors:  Mario Muto; Gianluigi Guarnieri; Francesco Giurazza; Luigi Manfrè
Journal:  Br J Radiol       Date:  2016-01-05       Impact factor: 3.039

4.  BCL2L1 is identified as a target of naringenin in regulating ovarian cancer progression.

Authors:  Jing Xu; Zhe Guo; Shuang Yuan; Heli Li
Journal:  Mol Cell Biochem       Date:  2022-02-19       Impact factor: 3.396

5.  Intraoperative PEEP-ventilation during PMMA-injection for augmented pedicle screws: improvement of leakage rate in spinal surgery.

Authors:  A El Saman; A Kelm; S Meier; A L Sander; K Eichler; I Marzi; H Laurer
Journal:  Eur J Trauma Emerg Surg       Date:  2013-08-20       Impact factor: 3.693

6.  A comparative study of high-viscosity cement percutaneous vertebroplasty vs. low-viscosity cement percutaneous kyphoplasty for treatment of osteoporotic vertebral compression fractures.

Authors:  Kai Sun; Yang Liu; Hao Peng; Jun-Feng Tan; Mi Zhang; Xian-Nian Zheng; Fang-Zhou Chen; Ming-Hui Li
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2016-07-05

7.  Modified poly(methyl methacrylate) bone cement in the treatment of Kümmell disease.

Authors:  Jinjin Zhu; Shuhui Yang; Yute Yang; Teng Yao; Gang Liu; Shunwu Fan; He Zhao; Fuzhai Cui; Xiumei Wang; Guoqiang Jiang; Xiangqian Fang
Journal:  Regen Biomater       Date:  2021-01-09

8.  Does Balloon Kyphoplasty Deliver More Cement Safely into Osteoporotic Vertebrae with Compression Fractures Compared with Vertebroplasty? A Study in Vertebral Analogues.

Authors:  Fahad H Abduljabbar; Abdulaziz Al-Jurayyan; Saad Alqahtani; Zeeshan M Sardar; Rajeet Singh Saluja; Jean Ouellet; Michael Weber; Thomas Steffen; Lorne Beckman; Peter Jarzem
Journal:  Global Spine J       Date:  2015-02-26

9.  Computer Simulation and Analysis on Flow Characteristics and Distribution Patterns of Polymethylmethacrylate in Lumbar Vertebral Body and Vertebral Pedicle.

Authors:  Da Liu; Xu-Li Liu; Bo Zhang; Dong-Fa Liao; Zhi-Qiang Li; Jiang-Jun Zhou; Xia Kang; Wei Zheng; Wei Lei
Journal:  Biomed Res Int       Date:  2015-12-07       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.