Marked troponin elevation after implantation of a permanent antibradycardia pacemaker.

Nikolaos I Nikolaou1, Apostolos H Christou, Stavros G Spanodimos, Dionysios G Antonatos, Panagiotis I Korkonikitas, Sotirios P Patsilinakos.   

Abstract

INTRODUCTION: Transvenous insertion of endocardial leads for permanent pacing is often accompanied by minor myocardial damage, detected thanks to the high sensitivity of cardiac troponins. It is unknown whether higher troponin levels, commensurate with more severe myocardial damage, can be encountered after implantation procedures.
METHODS: Over a 3-year period, 283 patients underwent an implantation of a full antibradycardia pacemaker system (pulse generator plus leads). Patients were required to have normal levels of cardiac troponin I (CTNI) on a venous blood sample taken immediately prior to elective pacemaker insertion. Post implantation CTNI levels were measured in all patients 6 hours after the procedure. Repeated samples were taken if high CTNI levels were found at 6 hours.
RESULTS: Elevated CTN-I levels were found in 167 patients (59%, 95% CI: 0.53-0.64), but only 5 of them (1.8%, 95% CI=0.8 to 4.1%) had peak CTN-I levels far exceeding the range of minimal myocardial damage (i.e. CTN-I >1.5 ng/ml). Implantation of the devices was successful in all patients and we did not observe any complications. None had clinical evidence of an acute coronary event before or during the pacemaker implantation procedure and coronary angiography revealed no significant lesions in the coronary arteries.
CONCLUSIONS: CTN-I elevations after pacemaker implantation may far exceed levels corresponding to minimal myocardial damage. This should be a matter of concern, especially if an early discharge is planned after pacemaker implantation.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22143011

Source DB:  PubMed          Journal:  Hellenic J Cardiol        ISSN: 1109-9666


  6 in total

1.  Troponin T elevation after permanent pacemaker implantation.

Authors:  Xueying Chen; Ziqing Yu; Jin Bai; Shulan Hu; Wei Wang; Shengmei Qin; Jingfeng Wang; Zhe Sun; Yangang Su; Junbo Ge
Journal:  J Interv Card Electrophysiol       Date:  2017-04-18       Impact factor: 1.900

2.  Biomarkers of Myocardial Injury and Inflammation after Permanent Pacemaker Implantation: The Lead Fixation Type Effect.

Authors:  Dimitrios Varvarousis; Nikolaos Goulas; Kali Polytarchou; Stavroula N Psychari; Konstantinos Paravolidakis; Agapi Konstantinidou; Dionysios Tsoukalas; Delia Vlad; Konstantina Bouki; Athanasios Kotsakis
Journal:  J Atr Fibrillation       Date:  2018-04-30

3.  Effects of permanent cardiac pacemaker implantation on vascular endothelial function, blood coagulation and cardiac function in patients with bradycardia.

Authors:  Xinling Zhang; Yan Li; Nan Wang; Chunxiang Zhang; Debing Zhang; Qiang Li
Journal:  Exp Ther Med       Date:  2018-09-28       Impact factor: 2.447

4.  Turkish Society of Cardiology consensus paper on the rational use of cardiac troponins in daily practice.

Authors:  Kaan Okyay; Beste Özben Sadıç; Asife Şahinarslan; Murtaza Emre Durakoğlugil; Can Yücel Karabay; Semiha Emel Eryüksel; Özlem Gülbahar; Abdullah Tekin; Aylin Yıldırır; Bülent Görenek; Oğuz Yavuzgil; Ali Serdar Fak
Journal:  Anatol J Cardiol       Date:  2019-04-19       Impact factor: 1.596

5.  Pacemaker Implantation Associated Myocardial Micro-Damage: A Randomised Comparison between Active and Passive Fixation Leads.

Authors:  Patrick Blažek; Jerko Ferri-Certić; Hrvoje Vražić; Carsten Lennerz; Christian Grebmer; Kazuaki Kaitani; Martin Karch; Boris Starčević; Verena Semmler; Christof Kolb
Journal:  Sci Rep       Date:  2018-03-20       Impact factor: 4.379

6.  Myocardial Injury After Temporary Transvenous Cardiac Pacing.

Authors:  Meng Liu; Pingsheng Wu
Journal:  Ther Clin Risk Manag       Date:  2021-05-18       Impact factor: 2.423

  6 in total