Literature DB >> 22142831

A multi-sample 94 GHz dissolution dynamic-nuclear-polarization system.

Michael Batel1, Marcin Krajewski, Kilian Weiss, Oliver With, Alexander Däpp, Andreas Hunkeler, Martin Gimersky, Klaas P Pruessmann, Peter Boesiger, Beat H Meier, Sebastian Kozerke, Matthias Ernst.   

Abstract

We describe the design and initial performance results of a multi-sample dissolution dynamic-nuclear-polarization (DNP) polarizer based on a Helium-temperature NMR cryostat for use in a wide-bore NMR magnet with a room-temperature bore. The system is designed to accommodate up to six samples in a revolver-style sample changer that allows changing samples at liquid-Helium temperature and at pressures ranging from ambient pressure down to 1 mbar. The multi-sample setup is motivated by the desire to do repetitive in vivo measurements and to characterize the DNP process by investigating samples of different chemical composition. The system can be loaded with up to six samples simultaneously to reduce sample loading and unloading. Therefore, series of experiments can be carried out faster and more reliably. The DNP probe contains an oversized microwave cavity and includes EPR and NMR capabilities for monitoring the DNP process. In the solid state, DNP enhancements corresponding to ∼45% polarization for [1-(13)C]pyruvic acid with a trityl radical have been measured. In the initial liquid-state acquisition experiments described here, the polarization was found to be ∼13%, corresponding to an enhancement factor exceeding 16,000 relative to thermal polarization at 9.4 T and ambient temperature.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22142831     DOI: 10.1016/j.jmr.2011.11.002

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  17 in total

1.  Non-invasive in vivo assessment of IDH1 mutational status in glioma.

Authors:  Myriam M Chaumeil; Peder E Z Larson; Hikari A I Yoshihara; Olivia M Danforth; Daniel B Vigneron; Sarah J Nelson; Russell O Pieper; Joanna J Phillips; Sabrina M Ronen
Journal:  Nat Commun       Date:  2013       Impact factor: 14.919

Review 2.  Metabolic and Molecular Imaging with Hyperpolarised Tracers.

Authors:  Jason Graham Skinner; Luca Menichetti; Alessandra Flori; Anna Dost; Andreas Benjamin Schmidt; Markus Plaumann; Ferdia Aiden Gallagher; Jan-Bernd Hövener
Journal:  Mol Imaging Biol       Date:  2018-12       Impact factor: 3.488

3.  A battery-driven, low-field NMR unit for thermally and hyperpolarized samples.

Authors:  Robert Borowiak; Niels Schwaderlapp; Frank Huethe; Thomas Lickert; Elmar Fischer; Sébastien Bär; Jürgen Hennig; Dominik von Elverfeldt; Jan-Bernd Hövener
Journal:  MAGMA       Date:  2013-02-15       Impact factor: 2.310

4.  Development and performance of a 129-GHz dynamic nuclear polarizer in an ultra-wide bore superconducting magnet.

Authors:  Lloyd L Lumata; Richard Martin; Ashish K Jindal; Zoltan Kovacs; Mark S Conradi; Matthew E Merritt
Journal:  MAGMA       Date:  2014-08-14       Impact factor: 2.310

5.  Influence of Dy3+ and Tb3+ doping on 13C dynamic nuclear polarization.

Authors:  Peter Niedbalski; Christopher Parish; Andhika Kiswandhi; Leila Fidelino; Chalermchai Khemtong; Zahra Hayati; Likai Song; André Martins; A Dean Sherry; Lloyd Lumata
Journal:  J Chem Phys       Date:  2017-01-07       Impact factor: 3.488

6.  A multisample 7 T dynamic nuclear polarization polarizer for preclinical hyperpolarized MR.

Authors:  Tian Cheng; Adam P Gaunt; Irene Marco-Rius; Marcel Gehrung; Albert P Chen; Jacques J van der Klink; Arnaud Comment
Journal:  NMR Biomed       Date:  2020-01-30       Impact factor: 4.044

7.  Affinity screening using competitive binding with fluorine-19 hyperpolarized ligands.

Authors:  Yaewon Kim; Christian Hilty
Journal:  Angew Chem Int Ed Engl       Date:  2015-02-20       Impact factor: 15.336

8.  Parallelized Ligand Screening Using Dissolution Dynamic Nuclear Polarization.

Authors:  Yaewon Kim; Mengxiao Liu; Christian Hilty
Journal:  Anal Chem       Date:  2016-10-25       Impact factor: 6.986

9.  Determination of binding affinities using hyperpolarized NMR with simultaneous 4-channel detection.

Authors:  Yaewon Kim; Mengxiao Liu; Christian Hilty
Journal:  J Magn Reson       Date:  2018-08-13       Impact factor: 2.229

10.  Multi-resonant photonic band-gap/saddle coil DNP probehead for static solid state NMR of microliter volume samples.

Authors:  Alexander A Nevzorov; Sergey Milikisiyants; Antonin N Marek; Alex I Smirnov
Journal:  J Magn Reson       Date:  2018-10-23       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.