Literature DB >> 22138585

Noninvasive, objective, multimodal tear dynamics evaluation of 5 over-the-counter tear drops in a randomized controlled trial.

Cynthia I Tung1, Ranjini Kottaiyan, Shizuka Koh, Qi Wang, Geunyoung Yoon, James M Zavislan, Steve R Davio, James V Aquavella.   

Abstract

PURPOSE: To assess the ability of a noninvasive, objective, multimodal system to compare the efficacy and optical quality of 4 different groups of 5 over-the-counter tear drops.
METHODS: Wavefront sensing and optical coherence tomography (OCT) were used to objectively assess visual quality and tear volume, respectively, after the over-the-counter tear drops [2 polyethylene glycol (PEG)-400, 1 carboxymethyl cellulose (CMC), 1 polyvinyl alcohol/PEG-400 (PVA), and 1 glycerine/polysorbate-80] were administered to 23 patients with aqueous-deficient dry eye in a randomized, controlled, double-masked trial. Measurements at each of the 5 visits were taken from both eyes at baseline and 5, 20, and 40 minutes after drop instillation.
RESULTS: At 5 minutes after drop instillation, the 2 PEG drops showed significant worsening of visual quality (-128.87%, P = 0.001) compared with CMC, PVA, and glycerine drops. Tear volume was elevated significantly with PEG and CMC drops at 5 minutes (+33.2%, P = 0.002; +29.9%, P < 0.001) compared with the other groups. Subjects with a Schirmer score of less than 5 mm at 5 minutes showed improvement in visual quality with PEG drops, whereas those with a fluorescein staining score of 1 to 2 showed improvement with both PEG and CMC drops. A trend toward decreasing visual quality with increasing tear meniscus was noted.
CONCLUSIONS: Noninvasive multimodal imaging has the potential to evaluate tear dynamics and the efficacy of artificial tears objectively. Certain artificial tear components and the temporary increase in tear volume after instillation of artificial tears may contribute to transient reduction of visual quality.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22138585     DOI: 10.1097/ICO.0b013e31821ea667

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  8 in total

Review 1.  Active agents, biomaterials, and technologies to improve biolubrication and strengthen soft tissues.

Authors:  Benjamin G Cooper; Ara Nazarian; Brian D Snyder; Mark W Grinstaff
Journal:  Biomaterials       Date:  2018-07-26       Impact factor: 12.479

2.  Ellipsometry of human tears.

Authors:  Ben J Glasgow
Journal:  Ocul Surf       Date:  2019-02-25       Impact factor: 5.033

3.  Tear meniscus dimensions in tear dysfunction and their correlation with clinical parameters.

Authors:  Cynthia I Tung; Andrew F Perin; Koray Gumus; Stephen C Pflugfelder
Journal:  Am J Ophthalmol       Date:  2013-09-28       Impact factor: 5.258

4.  Long-term results of treatment with diquafosol ophthalmic solution for aqueous-deficient dry eye.

Authors:  Shizuka Koh; Chikako Ikeda; Yoshihiro Takai; Hitoshi Watanabe; Naoyuki Maeda; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2013-06-06       Impact factor: 2.447

5.  Safety of Lifitegrast Ophthalmic Solution 5.0% in Patients With Dry Eye Disease: A 1-Year, Multicenter, Randomized, Placebo-Controlled Study.

Authors:  Eric D Donnenfeld; Paul M Karpecki; Parag A Majmudar; Kelly K Nichols; Aparna Raychaudhuri; Monica Roy; Charles P Semba
Journal:  Cornea       Date:  2016-06       Impact factor: 2.651

6.  Shear-Thinning and Temperature-Dependent Viscosity Relationships of Contemporary Ocular Lubricants.

Authors:  Wasim Kapadia; Ning Qin; Pei Zhao; Chau-Minh Phan; Lacey Haines; Lyndon Jones; Carolyn L Ren
Journal:  Transl Vis Sci Technol       Date:  2022-03-02       Impact factor: 3.283

7.  Effect of artificial tears on dynamic optical quality in patients with dry eye disease.

Authors:  Zhenyu Wei; Yuandong Su; Guanyu Su; Christophe Baudouin; Antoine Labbé; Qingfeng Liang
Journal:  BMC Ophthalmol       Date:  2022-02-10       Impact factor: 2.209

8.  Effect of Ultrasonic Moisture Glasses on Dry Eye Signs and Symptoms.

Authors:  Shuhei Onomura; Motoko Kawashima; Naohiko Aketa; Shinichiro Kondo; Kazuo Tsubota
Journal:  Transl Vis Sci Technol       Date:  2018-10-01       Impact factor: 3.283

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.