Literature DB >> 22137802

Beyond the short-term: clinical outcome and valve performance 2 years after transcatheter aortic valve implantation in 227 patients.

Sabine Bleiziffer1, Domenico Mazzitelli, Anke Opitz, Ina Hettich, Hendrik Ruge, Nicolo Piazza, Rüdiger Lange.   

Abstract

OBJECTIVE: Although the procedural feasibility of transcatheter aortic valve implantation has been shown by multiple groups, longer-term data are rare. We report on 2-year follow-up clinical and echocardiographic results after transcatheter aortic valve implantation in 227 patients.
METHODS: Patients' mean age was 81 ± 7 years, 59% were female, mean European System for Cardiac Operative Risk Evaluation was 21% ± 14%, mean Society of Thoracic Surgeons score was 7% ± 5%, and access routes were transfemoral (n = 164), transapical (n = 54), axillary (n = 5), or transaortic (n = 4). A CoreValve (Medtronic Inc, Minneapolis, Minn) prosthesis was implanted in 174 patients, and a SAPIEN prosthesis (Edwards Lifesciences, Irvine, Calif) was implanted in 53 patients. Clinical and echocardiographic investigations were performed at 6 months, 1 year, and 2 years.
RESULTS: Survival was 88.5% at 30 days, 75.9% at 6 months, 74.5% at 1 year, and 64.4% at 2 years. Patients improved significantly in New York Heart Association class after 6 months (from 3.2 ± 0.5 to 1.7 ± 0.7, P < .001) and up to 2 years (1.9 ± 0.7). Cumulative incidences of myocardial infarction, stroke, and life-threatening or major bleeding were 2.7%, 6.2%, and 16.2% at 2 years, respectively. The postprocedural mean transprosthetic gradient was 12 ± 4 mm Hg for all valves and did not change up to 2 years, and the effective orifice area was 1.5 ± 0.4 cm² with no change over 2 years of follow-up. Moderate or severe prosthetic regurgitation was present in 8% of patients at 2 years. In 6% of patients, the paravalvular or valvular regurgitation grade increased significantly over time.
CONCLUSIONS: With excellent functional recovery of the patients, good systolic valve function, and overall low morbidity at 2 years, transcatheter aortic valve implantation may be considered the treatment of choice for aortic valve stenosis in elderly patients with an increased risk for surgery with a heart-lung machine.
Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22137802     DOI: 10.1016/j.jtcvs.2011.10.060

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  14 in total

1.  Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre.

Authors:  Dayimi Kaya; Zulkif Tanriverdi; Huseyin Dursun; Tugce Colluoglu
Journal:  Int J Cardiovasc Imaging       Date:  2016-06-09       Impact factor: 2.357

2.  Insights on mid-term TAVR performance: 3-year clinical and echocardiographic results from the CoreValve ADVANCE study.

Authors:  Sabine Bleiziffer; Johan Bosmans; Stephen Brecker; Ulrich Gerckens; Peter Wenaweser; Corrado Tamburino; Axel Linke
Journal:  Clin Res Cardiol       Date:  2017-05-08       Impact factor: 5.460

Review 3.  Efficacy of transcatheter aortic valve implantation in patients with aortic stenosis and reduced LVEF. A systematic review.

Authors:  X Luo; Z Zhao; H Chai; C Zhang; Y Liao; Q Li; Y Peng; W Liu; X Ren; Q Meng; C Chen; M Chen; Y Feng; D Huang
Journal:  Herz       Date:  2015-02-26       Impact factor: 1.443

4.  Evaluation of the Valve Academic Research Consortium-2 Criteria for Myocardial Infarction in Transcatheter Aortic Valve Implantation: A Prospective Observational Study.

Authors:  Lennart Nilsson; Carl-Fredrik Appel; Henrik Hultkvist; Farkas Vánky
Journal:  PLoS One       Date:  2015-06-12       Impact factor: 3.240

Review 5.  Long-term results after transcatheter aortic valve implantation: what do we know today?

Authors:  Y Elhmidi; S Bleiziffer; N Piazza; B Voss; M Krane; M-A Deutsch; R Lange
Journal:  Curr Cardiol Rev       Date:  2013-11

Review 6.  Beyond adding years to life: health-related quality-of-life and functional outcomes in patients with severe aortic valve stenosis at high surgical risk undergoing transcatheter aortic valve replacement.

Authors:  Marcus-Andre Deutsch; Sabine Bleiziffer; Yacine Elhmidi; Nicolo Piazza; Bernhard Voss; Ruediger Lange; Markus Krane
Journal:  Curr Cardiol Rev       Date:  2013-11

7.  Challenges in cardiac device innovation: is neuroimaging an appropriate endpoint? Consensus from the 2013 Yale-UCL Cardiac Device Innovation Summit.

Authors:  Stephanie M Meller; Andreas Baumbach; Szilard Voros; Michael Mullen; Alexandra J Lansky
Journal:  BMC Med       Date:  2013-12-11       Impact factor: 8.775

Review 8.  Functional status and quality of life after transcatheter aortic valve replacement: a systematic review.

Authors:  Caroline A Kim; Suraj P Rasania; Jonathan Afilalo; Jeffrey J Popma; Lewis A Lipsitz; Dae Hyun Kim
Journal:  Ann Intern Med       Date:  2014-02-18       Impact factor: 25.391

9.  Early and intermediate survival after transcatheter aortic valve implantation: systematic review and meta-analysis of 14 studies.

Authors:  Andrea Messori; Sabrina Trippoli; Fausto Biancari
Journal:  BMJ Open       Date:  2013-01-11       Impact factor: 2.692

10.  A review of most relevant complications of transcatheter aortic valve implantation.

Authors:  Siyamek Neragi-Miandoab; Robert E Michler
Journal:  ISRN Cardiol       Date:  2013-05-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.