Literature DB >> 22137675

Automated frequency domain analysis of oxygen saturation as a screening tool for SAHS.

Daniel Sánchez Morillo1, Nicole Gross, Antonio León, Luis F Crespo.   

Abstract

Sleep apnea-hypopnea syndrome (SAHS) is significantly underdiagnosed and new screening systems are needed. The analysis of oxygen desaturation has been proposed as a screening method. However, when oxygen saturation (SpO(2)) is used as a standalone single channel device, algorithms working in time domain achieve either a high sensitivity or a high specificity, but not usually both. This limitation arises from the dependence of time-domain analysis on absolute SpO(2) values and the lack of standardized thresholds defined as pathological. The aim of this study is to assess the degree of concordance between SAHS screening using offline frequency domain processing of SpO(2) signals and the apnea-hypopnea index (AHI), and the diagnostic performance of such a new method. SpO(2) signals from 115 subjects were analyzed. Data were divided in a training data set (37) and a test set (78). Power spectral density was calculated and related to the desaturation index scored by physicians. A frequency desaturation index (FDI) was then estimated and its accuracy compared to the classical desaturation index and to the apnea-hypopnea index. The findings point to a high diagnostic agreement: the best sensitivity and specificity values obtained were 83.33% and 80.44%, respectively. Moreover, the proposed method does not rely on absolute SpO(2) values and is highly robust to artifacts.
Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22137675     DOI: 10.1016/j.medengphy.2011.10.015

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  6 in total

1.  Probabilistic neural network approach for the detection of SAHS from overnight pulse oximetry.

Authors:  Daniel Sánchez Morillo; Nicole Gross
Journal:  Med Biol Eng Comput       Date:  2012-11-18       Impact factor: 2.602

2.  New Rule-Based Algorithm for Real-Time Detecting Sleep Apnea and Hypopnea Events Using a Nasal Pressure Signal.

Authors:  Hyoki Lee; Jonguk Park; Hojoong Kim; Kyoung-Joung Lee
Journal:  J Med Syst       Date:  2016-10-27       Impact factor: 4.460

3.  A novel, simple, and accurate pulse oximetry indicator for screening adult obstructive sleep apnea.

Authors:  Carlos Alberto Nigro; Gonzalo Castaño; Ignacio Bledel; Alfredo Colombi; María Cecilia Zicari
Journal:  Sleep Breath       Date:  2021-09-23       Impact factor: 2.655

Review 4.  Computer-Assisted Diagnosis of the Sleep Apnea-Hypopnea Syndrome: A Review.

Authors:  Diego Alvarez-Estevez; Vicente Moret-Bonillo
Journal:  Sleep Disord       Date:  2015-07-21

5.  Feasibility of Single Channel Oximetry for Mass Screening of Obstructive Sleep Apnea.

Authors:  Joachim A Behar; Niclas Palmius; Qiao Li; Silverio Garbuio; Fabìola P G Rizzatti; Lia Bittencourt; Sergio Tufik; Gari D Clifford
Journal:  EClinicalMedicine       Date:  2019-06-07

6.  Diagnostic accuracy of oximetry for obstructive sleep apnea: a study on older adults in a home setting.

Authors:  João Carlos Fraga da Rosa; Alessandra Peres; Luciano Gasperin Júnior; Denis Martinez; Vania Fontanella
Journal:  Clinics (Sao Paulo)       Date:  2021-10-01       Impact factor: 2.365