Literature DB >> 22137253

Strain, strain rate, and the force frequency relationship in patients with and without heart failure.

Susanna Mak1, Harriette G C Van Spall, Rodrigo V Wainstein, Zion Sasson.   

Abstract

BACKGROUND: The aim of this study was to examine the effect of heart rate (HR) on indices of deformation in adults with and without heart failure (HF) who underwent simultaneous high-fidelity catheterization of the left ventricle to describe the force-frequency relationship.
METHODS: Right atrial pacing to control HR and high-fidelity recordings of left ventricular (LV) pressure were used to inscribe the force-frequency relationship. Simultaneous two-dimensional echocardiographic imaging was acquired for speckle-tracking analysis.
RESULTS: Thirteen patients with normal LV function and 12 with systolic HF (LV ejection fraction, 31 ± 13%) were studied. Patients with HF had depressed isovolumic contractility and impaired longitudinal strain and strain rate. HR-dependent increases in LV+dP/dt(max), the force-frequency relationship, was demonstrated in both groups (normal LV function, baseline to 100 beats/min: 1,335 ± 296 to 1,564 ± 320 mm Hg/sec, P < .0001; HF, baseline to 100 beats/min: 970 ± 207 to 1,083 ± 233 mm Hg/sec, P < .01). Longitudinal strain decreased significantly (normal LV function, baseline to 100 beats/min: 18.0 ± 3.5% to 10.8 ± 6.0%, P < .001; HF: 9.4 ± 4.1% to 7.5 ± 3.4%, P < .01). The decrease in longitudinal strain was related to a decrease in LV end-diastolic dimensions. Strain rate did not change with right atrial pacing.
CONCLUSIONS: Despite the inotropic effect of increasing HR, longitudinal strain decreases in parallel with stroke volume as load-dependent indices of ejection. Strain rate did not reflect the modest HR-related changes in contractility; on the other hand, the use of strain rate for quantitative stress imaging is also less likely to be confounded by chronotropic responses. Copyright Â
© 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22137253     DOI: 10.1016/j.echo.2011.11.008

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  4 in total

1.  Kept in the loop: longitudinal strain-volume relationships for the assessment of left ventricular mechanical performance.

Authors:  Stephen P Wright; Robert Lakin; Denise J Wooding; Leah Groves
Journal:  J Physiol       Date:  2017-07-30       Impact factor: 5.182

2.  Are measures of left ventricular systolic performance during low dose dobutamine stress echocardiograms repeatable over time?

Authors:  Nader H Elmayergi; Jack M Goodman; Leanna S Lee; Zion Sasson
Journal:  Int J Cardiovasc Imaging       Date:  2013-04-16       Impact factor: 2.357

3.  Mitral valve pressure gradient after percutaneous mitral valve repair: every beat counts.

Authors:  Daniel Lavall; Bruno Scheller; Christian Werner; Axel Buob; Felix Mahfoud
Journal:  ESC Heart Fail       Date:  2017-11-23

4.  Combination of single quantitative parameters into multiparametric model for ischemia detection is not superior to visual assessment during dobutamine stress echocardiography.

Authors:  Jelena Čelutkienė; Greta Burneikaitė; Linas Petkevičius; Laura Balkevičienė; Aleksandras Laucevičius
Journal:  Cardiovasc Ultrasound       Date:  2016-04-12       Impact factor: 2.062

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.